Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Chemical_master_Chemical.Examples.SimpleReactionsWithJunction2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001262/0.001262, allocations: 95.77 kB / 18.94 MB, free: 2.844 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001462/0.001462, allocations: 219.3 kB / 22.25 MB, free: 5.094 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.383/1.383, allocations: 230.6 MB / 256 MB, free: 7.812 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo): time 0.1283/0.1283, allocations: 23.92 MB / 336.4 MB, free: 10.97 MB / 270.1 MB " [Timeout remaining time 180] Using package Chemical with version 2.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Chemical.Examples.SimpleReactionsWithJunction2,fileNamePrefix="Chemical_master_Chemical_Examples_SimpleReactionsWithJunction2",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Chemical.Examples.SimpleReactionsWithJunction2,fileNamePrefix="Chemical_master_Chemical_Examples_SimpleReactionsWithJunction2",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Chemical requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001916/0.001916, allocations: 63.91 kB / 471.2 MB, free: 7.52 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3066/0.3085, allocations: 59.87 MB / 0.5186 GB, free: 9.48 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1098:7-1098:40:writable] Warning: An inner declaration for outer component dropOfCommons could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1098:7-1098:40:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"dropOfCommons\" component but an inner \"dropOfCommons\" component is not defined. Use Chemical.DropOfCommons in your model to specify system properties. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1697:7-1697:66:writable] Warning: An inner declaration for outer component system could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1697:7-1697:66:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"system\" component but an inner \"system\" component is not defined. For simulation drag Modelica.Fluid.System into your model to specify system properties. Notification: Performance of NFInst.instantiate(Chemical.Examples.SimpleReactionsWithJunction2): time 0.0774/0.3859, allocations: 34.21 MB / 0.552 GB, free: 5.961 MB / 398.1 MB Notification: Performance of NFInst.instExpressions: time 0.01881/0.4047, allocations: 9.992 MB / 0.5618 GB, free: 12.98 MB / 414.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.003672/0.4084, allocations: 71.62 kB / 0.5618 GB, free: 12.91 MB / 414.1 MB Notification: Performance of NFTyping.typeComponents: time 0.005918/0.4143, allocations: 1.961 MB / 0.5637 GB, free: 11.36 MB / 414.1 MB Notification: Performance of NFTyping.typeBindings: time 0.006425/0.4207, allocations: 1.52 MB / 0.5652 GB, free: 10.08 MB / 414.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.008642/0.4293, allocations: 3.679 MB / 0.5688 GB, free: 6.449 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1311:3-1311:46:writable] Error: Parameter r.nextProducts[1].data.MM has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0007797/0.4301, allocations: 306.4 kB / 0.5691 GB, free: 6.148 MB / 414.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.7388251810043585] Failed to read output from testmodel.py, exit status != 0: 0.4362883360008709 0.451607943 -1.0 Calling exit ...