OMSimulator --tempDir=temp_Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction_fmu --startTime=0 --stopTime=36000 --timeout=50 --tolerance=1e-08 Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction.fmu warning: Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28: The following assertion has been violated during initialization at time 0.000000 not senCO2.warnAboutOnePortConnection assert | warning | Sensor Buildings.Fluid.Sensors.Conversions.Examples.To_VolumeFraction.senCO2 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'Buildings.Fluid.MixingVolumes`. | | | | See Buildings.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in Buildings.Fluid.Sensors.Conversions.Examples.To_VolumeFraction.senCO2. info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction.senCO2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction.senCO2.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction.senTraSubFre.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction.senTraSubPeo.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_8_0_x_Buildings_Fluid_Sensors_Conversions_Examples_To_VolumeFraction.souCO2.substanceName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 1 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 790680 NumRhsEvals = 790681 NumLinSolvSetups = 39535 NumNonlinSolvIters = 790680 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21