Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTube.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTube,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTube,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.337/1.337, allocations: 251.5 MB / 266.7 MB, free: 11.05 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00111/0.00111, allocations: 181.4 kB / 325.9 MB, free: 2.691 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.404/1.404, allocations: 205 MB / 0.576 GB, free: 20.98 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0006976/0.0006977, allocations: 83.98 kB / 0.6797 GB, free: 14.71 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003312/0.0003314, allocations: 15.03 kB / 0.7933 GB, free: 136.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.19/0.1904, allocations: 105.4 MB / 0.8963 GB, free: 68.04 MB / 0.6042 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTube): time 0.001293/0.1917, allocations: 1.173 MB / 0.8974 GB, free: 66.85 MB / 0.6042 GB Notification: Performance of NFInst.instExpressions: time 0.003354/0.1951, allocations: 3.057 MB / 0.9004 GB, free: 63.78 MB / 0.6042 GB Notification: Performance of NFInst.updateImplicitVariability: time 3.786e-05/0.1951, allocations: 4 kB / 0.9004 GB, free: 63.77 MB / 0.6042 GB Notification: Performance of NFTyping.typeComponents: time 2.37e-05/0.1952, allocations: 3.938 kB / 0.9004 GB, free: 63.77 MB / 0.6042 GB Notification: Performance of NFTyping.typeBindings: time 5.255e-05/0.1952, allocations: 7.922 kB / 0.9004 GB, free: 63.76 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/Boreholes/BaseClasses/Functions/internalResistancesOneUTube.mo:2:1-155:32:writable] Warning: Pure function ‘Buildings.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.internalResistancesOneUTube‘ contains a call to impure function ‘Modelica.Utilities.Streams.print‘. Notification: Performance of NFTyping.typeClassSections: time 0.002966/0.1982, allocations: 1.443 MB / 0.9018 GB, free: 62.34 MB / 0.6042 GB Notification: Performance of NFFlatten.flatten: time 5.437e-05/0.1983, allocations: 47.67 kB / 0.9019 GB, free: 62.29 MB / 0.6042 GB Notification: Performance of NFFlatten.resolveConnections: time 3.68e-05/0.1983, allocations: 0 / 0.9019 GB, free: 62.29 MB / 0.6042 GB Notification: Performance of NFEvalConstants.evaluate: time 2.307e-05/0.1983, allocations: 15.92 kB / 0.9019 GB, free: 62.28 MB / 0.6042 GB Notification: Performance of NFSimplifyModel.simplify: time 1.982e-05/0.1984, allocations: 15.94 kB / 0.9019 GB, free: 62.26 MB / 0.6042 GB Notification: Performance of NFPackage.collectConstants: time 8.626e-06/0.1984, allocations: 0 / 0.9019 GB, free: 62.26 MB / 0.6042 GB Notification: Performance of NFFlatten.collectFunctions: time 0.001653/0.2, allocations: 1.447 MB / 0.9033 GB, free: 60.81 MB / 0.6042 GB Notification: Performance of NFScalarize.scalarize: time 1.174e-05/0.2001, allocations: 11.88 kB / 0.9033 GB, free: 60.8 MB / 0.6042 GB Notification: Performance of NFVerifyModel.verify: time 2.676e-05/0.2001, allocations: 19.88 kB / 0.9033 GB, free: 60.78 MB / 0.6042 GB Notification: Performance of NFConvertDAE.convert: time 0.001083/0.2012, allocations: 1.099 MB / 0.9044 GB, free: 59.68 MB / 0.6042 GB Notification: Performance of FrontEnd - DAE generated: time 3.637e-06/0.2012, allocations: 0 / 0.9044 GB, free: 59.68 MB / 0.6042 GB Notification: Performance of FrontEnd: time 1.513e-06/0.2012, allocations: 0 / 0.9044 GB, free: 59.68 MB / 0.6042 GB Notification: Performance of Transformations before backend: time 4.027e-06/0.2012, allocations: 0 / 0.9044 GB, free: 59.68 MB / 0.6042 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 0 * Number of variables: 0 Notification: Performance of Generate backend data structure: time 0.0004165/0.2016, allocations: 0.5159 MB / 0.9049 GB, free: 59.12 MB / 0.6042 GB Notification: Performance of prepare preOptimizeDAE: time 3.772e-05/0.2017, allocations: 12.03 kB / 0.9049 GB, free: 59.11 MB / 0.6042 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 2.734e-05/0.2017, allocations: 106 kB / 0.905 GB, free: 58.99 MB / 0.6042 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 4.433e-05/0.2018, allocations: 84.22 kB / 0.9051 GB, free: 58.91 MB / 0.6042 GB Notification: Performance of preOpt evaluateParameters (simulation): time 8.119e-05/0.2019, allocations: 243.6 kB / 0.9053 GB, free: 58.63 MB / 0.6042 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 2.13e-05/0.2019, allocations: 154.9 kB / 0.9055 GB, free: 58.48 MB / 0.6042 GB Notification: Performance of preOpt expandDerOperator (simulation): time 2.188e-05/0.2019, allocations: 150.9 kB / 0.9056 GB, free: 58.33 MB / 0.6042 GB Notification: Performance of preOpt clockPartitioning (simulation): time 3.592e-05/0.202, allocations: 104.9 kB / 0.9057 GB, free: 58.22 MB / 0.6042 GB Notification: Performance of preOpt findStateOrder (simulation): time 1.143e-05/0.202, allocations: 75.28 kB / 0.9058 GB, free: 58.15 MB / 0.6042 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 1.923e-05/0.202, allocations: 154.6 kB / 0.9059 GB, free: 58 MB / 0.6042 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 1.741e-05/0.202, allocations: 150.6 kB / 0.9061 GB, free: 57.85 MB / 0.6042 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 1.979e-05/0.202, allocations: 162.5 kB / 0.9062 GB, free: 57.69 MB / 0.6042 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.0001615/0.2022, allocations: 457.8 kB / 0.9067 GB, free: 57.19 MB / 0.6042 GB Notification: Performance of preOpt comSubExp (simulation): time 4.225e-05/0.2023, allocations: 181.1 kB / 0.9069 GB, free: 57 MB / 0.6042 GB Notification: Performance of preOpt resolveLoops (simulation): time 1.511e-05/0.2023, allocations: 80.14 kB / 0.9069 GB, free: 56.92 MB / 0.6042 GB Notification: Performance of preOpt evalFunc (simulation): time 1.007e-05/0.2023, allocations: 79.22 kB / 0.907 GB, free: 56.84 MB / 0.6042 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 1.843e-05/0.2023, allocations: 113.8 kB / 0.9071 GB, free: 56.72 MB / 0.6042 GB Notification: Performance of pre-optimization done (n=0): time 1.713e-06/0.2023, allocations: 3.984 kB / 0.9071 GB, free: 56.72 MB / 0.6042 GB Notification: Performance of matching and sorting (n=0): time 5.847e-05/0.2024, allocations: 29.7 kB / 0.9071 GB, free: 56.68 MB / 0.6042 GB Notification: Performance of inlineWhenForInitialization (initialization): time 2.607e-05/0.2024, allocations: 130.7 kB / 0.9073 GB, free: 56.54 MB / 0.6042 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 9.614e-05/0.2025, allocations: 133.7 kB / 0.9074 GB, free: 56.4 MB / 0.6042 GB Notification: Performance of collectPreVariables (initialization): time 6.042e-06/0.2025, allocations: 25.7 kB / 0.9074 GB, free: 56.37 MB / 0.6042 GB Notification: Performance of collectInitialEqns (initialization): time 2.933e-05/0.2026, allocations: 100.1 kB / 0.9075 GB, free: 56.27 MB / 0.6042 GB Notification: Performance of collectInitialBindings (initialization): time 2.585e-06/0.2026, allocations: 0 / 0.9075 GB, free: 56.27 MB / 0.6042 GB Notification: Performance of simplifyInitialFunctions (initialization): time 1.792e-05/0.2026, allocations: 13.66 kB / 0.9075 GB, free: 56.25 MB / 0.6042 GB Notification: Performance of setup shared object (initialization): time 3.998e-05/0.2026, allocations: 318.8 kB / 0.9078 GB, free: 55.93 MB / 0.6042 GB Notification: Performance of preBalanceInitialSystem (initialization): time 1.722e-05/0.2027, allocations: 4 kB / 0.9078 GB, free: 55.93 MB / 0.6042 GB Notification: Performance of partitionIndependentBlocks (initialization): time 1.181e-05/0.2027, allocations: 7.984 kB / 0.9078 GB, free: 55.92 MB / 0.6042 GB Notification: Performance of analyzeInitialSystem (initialization): time 2.985e-05/0.2027, allocations: 20.8 kB / 0.9079 GB, free: 55.89 MB / 0.6042 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 1.413e-06/0.2027, allocations: 0 / 0.9079 GB, free: 55.89 MB / 0.6042 GB Notification: Performance of matching and sorting (n=4) (initialization): time 9.488e-05/0.2028, allocations: 45.64 kB / 0.9079 GB, free: 55.84 MB / 0.6042 GB Notification: Performance of prepare postOptimizeDAE: time 1.086e-05/0.2028, allocations: 4 kB / 0.9079 GB, free: 55.84 MB / 0.6042 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 1.609e-05/0.2029, allocations: 7.984 kB / 0.9079 GB, free: 55.83 MB / 0.6042 GB Notification: Performance of postOpt tearingSystem (initialization): time 9.347e-06/0.2029, allocations: 0 / 0.9079 GB, free: 55.83 MB / 0.6042 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 7.91e-07/0.2029, allocations: 0 / 0.9079 GB, free: 55.83 MB / 0.6042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 4.148e-06/0.2029, allocations: 0 / 0.9079 GB, free: 55.83 MB / 0.6042 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 1.884e-05/0.2029, allocations: 11.84 kB / 0.9079 GB, free: 55.82 MB / 0.6042 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 6.422e-06/0.2029, allocations: 4.062 kB / 0.9079 GB, free: 55.82 MB / 0.6042 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1): * Single equations (assignments): 0 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 1 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of prepare postOptimizeDAE: time 4.934e-05/0.203, allocations: 183.3 kB / 0.9081 GB, free: 55.63 MB / 0.6042 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 3.461e-05/0.203, allocations: 112.9 kB / 0.9082 GB, free: 55.51 MB / 0.6042 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 2.43e-05/0.203, allocations: 116.8 kB / 0.9083 GB, free: 55.39 MB / 0.6042 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 1.975e-05/0.2031, allocations: 180.2 kB / 0.9085 GB, free: 55.2 MB / 0.6042 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 2.246e-05/0.2031, allocations: 184.3 kB / 0.9087 GB, free: 55.02 MB / 0.6042 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 1.975e-05/0.2031, allocations: 176.3 kB / 0.9088 GB, free: 54.84 MB / 0.6042 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.0001287/0.2033, allocations: 421.1 kB / 0.9092 GB, free: 54.37 MB / 0.6042 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.298e-05/0.2033, allocations: 105 kB / 0.9093 GB, free: 54.26 MB / 0.6042 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 1.255e-05/0.2033, allocations: 105.1 kB / 0.9094 GB, free: 54.15 MB / 0.6042 GB Notification: Performance of postOpt tearingSystem (simulation): time 2.158e-05/0.2033, allocations: 180.3 kB / 0.9096 GB, free: 53.96 MB / 0.6042 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 2.281e-05/0.2033, allocations: 184.3 kB / 0.9098 GB, free: 53.78 MB / 0.6042 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 2e-05/0.2034, allocations: 180.2 kB / 0.91 GB, free: 53.59 MB / 0.6042 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.972e-05/0.2034, allocations: 176.3 kB / 0.9101 GB, free: 53.41 MB / 0.6042 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 5.496e-05/0.2035, allocations: 323.6 kB / 0.9104 GB, free: 53.07 MB / 0.6042 GB Notification: Performance of postOpt removeConstants (simulation): time 2.854e-05/0.2035, allocations: 186 kB / 0.9106 GB, free: 52.87 MB / 0.6042 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 3.12e-05/0.2035, allocations: 184.2 kB / 0.9108 GB, free: 52.68 MB / 0.6042 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 4.844e-05/0.2036, allocations: 109 kB / 0.9109 GB, free: 52.57 MB / 0.6042 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 2.721e-05/0.2036, allocations: 180.2 kB / 0.9111 GB, free: 52.38 MB / 0.6042 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 1.095e-05/0.2036, allocations: 101 kB / 0.9112 GB, free: 52.28 MB / 0.6042 GB Notification: Performance of sorting global known variables: time 3.311e-05/0.2037, allocations: 97.77 kB / 0.9113 GB, free: 52.18 MB / 0.6042 GB Notification: Performance of sort global known variables: time 1e-07/0.2037, allocations: 0 / 0.9113 GB, free: 52.18 MB / 0.6042 GB Notification: Performance of remove unused functions: time 0.0005793/0.2043, allocations: 295.7 kB / 0.9115 GB, free: 51.89 MB / 0.6042 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 1 * Number of states: 0 () * Number of discrete variables: 0 () * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (0): * Single equations (assignments): 0 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of Backend phase and start with SimCode phase: time 0.0009896/0.2053, allocations: 1.172 MB / 0.9127 GB, free: 50.7 MB / 0.6042 GB Notification: Performance of simCode: created initialization part: time 8.602e-05/0.2053, allocations: 37.69 kB / 0.9127 GB, free: 50.66 MB / 0.6042 GB Notification: Performance of simCode: created event and clocks part: time 2.635e-06/0.2054, allocations: 4 kB / 0.9127 GB, free: 50.66 MB / 0.6042 GB Notification: Performance of simCode: created simulation system equations: time 2.444e-06/0.2054, allocations: 0 / 0.9127 GB, free: 50.66 MB / 0.6042 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.0002768/0.2057, allocations: 0.5224 MB / 0.9132 GB, free: 50.13 MB / 0.6042 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.0008513/0.2065, allocations: 1.574 MB / 0.9148 GB, free: 48.48 MB / 0.6042 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 8.704e-05/0.2066, allocations: 0.6887 MB / 0.9154 GB, free: 47.76 MB / 0.6042 GB Notification: Performance of simCode: alias equations: time 1.32e-05/0.2066, allocations: 3.906 kB / 0.9155 GB, free: 47.76 MB / 0.6042 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 2.001e-05/0.2067, allocations: 11.44 kB / 0.9155 GB, free: 47.75 MB / 0.6042 GB Notification: Performance of SimCode: time 2.6e-07/0.2067, allocations: 8.031 kB / 0.9155 GB, free: 47.74 MB / 0.6042 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.3307/0.5373, allocations: 6.829 MB / 0.9221 GB, free: 41.14 MB / 0.6042 GB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.0002019/0.5376, allocations: 350.3 kB / 0.9225 GB, free: 40.75 MB / 0.6042 GB Error: Error building simulator. Build log: clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube.c:7: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_functions.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_functions.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_functions.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_records.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_records.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_01exo.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_01exo.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_01exo.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_02nls.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_02nls.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_02nls.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_03lsy.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_03lsy.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_03lsy.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_04set.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_04set.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_04set.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_05evt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_05evt.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_05evt.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_06inz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_06inz.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_06inz.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_07dly.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_07dly.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_07dly.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_08bnd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_08bnd.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_08bnd.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_09alg.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_09alg.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_09alg.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_10asr.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_10asr.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_10asr.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_11mix.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_11mix.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_11mix.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_12jac.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_12jac.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_12jac.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_13opt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_13opt.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_13opt.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_14lnz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_14lnz.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_14lnz.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_15syn.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_15syn.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_15syn.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_16dae.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_16dae.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_16dae.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_17inl.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_17inl.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_17inl.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_18spd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_18spd.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_18spd.c:2: In file included from ./Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_init_fmu.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_init_fmu.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I. -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_FMU.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_FMU.c In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:155: ./gc/omc_gc.h:223:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:227:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_FMU.c:59: ./fmi-export/fmu2_model_interface.c.inc:213:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 3 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube.so Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_functions.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_records.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_01exo.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_02nls.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_03lsy.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_04set.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_05evt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_06inz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_07dly.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_08bnd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_09alg.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_10asr.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_11mix.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_12jac.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_13opt.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_14lnz.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_15syn.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_16dae.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_17inl.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_18spd.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_init_fmu.o Buildings_maint_7_0_x_Buildings_Fluid_Geothermal_Borefields_BaseClasses_Boreholes_BaseClasses_Functions_Validation_InternalResistancesOneUTube_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Geothermal/Borefields/BaseClasses/Boreholes/BaseClasses/Functions/Validation" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-Bstatic -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -Wl,-Bdynamic -lm -lpthread -rdynamic -Wl,--no-undefined /usr/bin/ld: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libModelicaExternalC.a(ModelicaInternal.c.o): in function `ModelicaInternal_temporaryFileName': ModelicaInternal.c:(.text+0xac7): warning: the use of `tmpnam' is dangerous, better use `mkstemp' /usr/bin/ld: /usr/bin/../lib/gcc/x86_64-linux-gnu/9/../../../x86_64-linux-gnu/liblapack.a(dtrtri.o): in function `dtrtri_': (.text+0x197): undefined reference to `_gfortran_concat_string' clang: error: linker command failed with exit code 1 (use -v to see invocation) make: *** [Makefile:65: nozip] Error 1