/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630_fmu --startTime=0 --stopTime=3.1536e+07 --stepSize=3600 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case630" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case630" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case630/model-blpzi1ec" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630.fmu - startTime: 0.000000 - stopTime: 31536000.000000 - tolerance: 0.000001 - stepSize: 3600.000000 info: maximum step size for 'model.root': 3600.000000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630.TSetCoo.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630.TSetCoo.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630.TSetHea.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ISO13790_Validation_BESTEST_Cases6xx_Case630.TSetHea.tableName will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 1.85109e+07, mxstep steps taken before reaching tout. error: [doStepCVODE] CVode failed with flag = -1 warning: Bad return code at time 18510855.893887 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 75441 NumRhsEvals = 107617 NumLinSolvSetups = 16503 NumNonlinSolvIters = 107616 NumNonlinSolvConvFails = 36 NumErrTestFails = 6532 info: 3 warnings info: 2 errors