/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones_fmu --startTime=0 --stopTime=604800 --stepSize=241.92 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones/model-j0f7xvqu" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones.fmu - startTime: 0.000000 - stopTime: 604800.000000 - tolerance: 0.000001 - stepSize: 241.920000 LOG_STDOUT | info | ... loading "EnergyPlus" from "/tmp/fmi4c_QKoNWj/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/Data/ThermalZones/EnergyPlus_24_2_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_ASSERT | debug | Solving non-linear system 198 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.ThermalZone.TwoIdenticalZones/model-j0f7xvqu/temp/0001_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Validation_ThermalZone_TwoIdenticalZones" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors