(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter_Autosizing_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Winter_Autosizing_fmu --startTime=432000 --stopTime=864000 --stepSize=900 --mode=me --timeout=240 --tolerance=1e-07 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Winter_Autosizing.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter_Autosizing (model exchange) - fmiVersion: 2.0 - startTime : 432000.000000 - stopTime : 864000.000000 - tolerance : 1e-07 - stepSize : 900 LOG_STDOUT | warning | The nominal value of flo.cor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.wes.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.nor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.eas.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.sou.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.splRetOut.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[5].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[5].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[5].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[4].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[4].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[4].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[3].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[3].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[3].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[2].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[2].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[2].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[1].terHea.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[1].terHea.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VAVBox[1].VSup_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.VOut1.V_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.senRetFlo.V_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.senSupFlo.V_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.fanSup.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.cooCoi.heaCooHum_u.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.heaCoi.C2_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.heaCoi.C1_flow is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.att.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.cooCoi.heaCoo.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.pumCooCoi.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of hvac.pumHeaCoi.vol.dynBal.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.17 07:35 Initializing Response Factors Calculating CTFs for "ATTIC NON-RES FLOOR" Calculating CTFs for "ATTIC NON-RES ROOF" Calculating CTFs for "INTERIORFURNISHINGS" Calculating CTFs for "MASS NON-RES EXT WALL" Calculating CTFs for "EXT-SLAB" Calculating CTFs for "INT-WALLS" Initializing Window Optical Properties Initializing Solar Calculations Allocate Solar Module Arrays Initializing Zone and Enclosure Report Variables Initializing Surface (Shading) Report Variables Determining Shadowing Combinations Computing Window Shade Absorption Factors Proceeding with Initializing Solar Calculations Initializing Surfaces Initializing Outdoor environment for Surfaces Setting up Surface Reporting Variables Initializing Temperature and Flux Histories Initializing Window Shading Computing Interior Absorption Factors Computing Interior Diffuse Solar Absorption Factors Initializing Solar Heat Gains Initializing Internal Heat Gains Initializing Interior Solar Distribution Initializing Interior Convection Coefficients Gathering Information for Predefined Reporting Completed Initializing Surface Heat Balance Calculate Outside Surface Heat Balance Calculate Inside Surface Heat Balance Calculate Air Heat Balance Initializing HVAC Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #1 CHICAGO ANN CLG .4% CONDNS WB=>MDB Warming up Warming up Warming up Warming up Warming up Warming up Performing Zone Sizing Simulation ...for Sizing Period: #2 CHICAGO ANN HTG 99.6% CONDNS DB Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101: The following assertion has been violated at time 432000.000000 ((hvac.fanSup.etaHyd >= 0.0), hvac.fanSup.etaHyd=-7.912966254722456e-26) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -7.91297e-26" warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46: The following assertion has been violated at time 432000.000000 ((hvac.fanSup.heaDis.etaHyd >= 0.0), hvac.fanSup.heaDis.etaHyd=-1.451087874761615e-21) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -1.45109e-21" warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70: The following assertion has been violated at time 432000.000000 ((hvac.VAVBox[1].VSup_flow >= 0.0), hvac.VAVBox[1].VSup_flow=-1.117796375416336e-13) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -1.1178e-13" warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70: The following assertion has been violated at time 432000.000000 ((hvac.VAVBox[2].VSup_flow >= 0.0), hvac.VAVBox[2].VSup_flow=-9.921674719476519e-14) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -9.92167e-14" warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70: The following assertion has been violated at time 432000.000000 ((hvac.VAVBox[3].VSup_flow >= 0.0), hvac.VAVBox[3].VSup_flow=-9.814810007914275e-14) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -9.81481e-14" warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70: The following assertion has been violated at time 432000.000000 ((hvac.VAVBox[4].VSup_flow >= 0.0), hvac.VAVBox[4].VSup_flow=-1.091553684256419e-13) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -1.09155e-13" warning: [fmi2Warning] Guideline36Winter_Autosizing/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70: The following assertion has been violated at time 432000.000000 ((hvac.VAVBox[5].VSup_flow >= 0.0), hvac.VAVBox[5].VSup_flow=-9.536122477617071e-14) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -9.53612e-14" info: maximum step size for 'Guideline36Winter_Autosizing.root': 900.000000 info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Winter_Autosizing_res.mat (bufferSize=10) info: Parameter Guideline36Winter_Autosizing.flo.att.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.att.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.cor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.cor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.eas.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.eas.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.epwName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.idfName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.nor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.nor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.sou.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.sou.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.sysVAV1.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.weaName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.wes.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.flo.wes.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Winter_Autosizing.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 453900.000000 | | | | ((hvac.conVAV[5].ala.not1.y), hvac.conVAV[5].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 453900.000000 | | | | ((hvac.conVAV[5].ala.not2.y), hvac.conVAV[5].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 456105.749183 | | | | ((hvac.conVAV[3].ala.not2.y), hvac.conVAV[3].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 456332.279586 | | | | ((hvac.conVAV[1].ala.not2.y), hvac.conVAV[1].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 456600.000000 | | | | ((hvac.conVAV[3].ala.not1.y), hvac.conVAV[3].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 470586.825641 | | | | ((not hvac.conVAV[4].ala.truDel6.y), hvac.conVAV[4].ala.truDel6.y=true) --> "Warning: the valve is leaking." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 578700.000000 | | | | ((hvac.conVAV[2].ala.not2.y), hvac.conVAV[2].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 842446.813777 | | | | ((not hvac.conVAV[3].ala.truDel6.y), hvac.conVAV[3].ala.truDel6.y=true) --> "Warning: the valve is leaking." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 842845.563889 | | | | ((not hvac.conVAV[2].ala.truDel6.y), hvac.conVAV[2].ala.truDel6.y=true) --> "Warning: the valve is leaking." Writing final SQL reports EnergyPlus Run Time=00hr 00min 32.32sec EnergyPlus Completed Successfully. info: Final Statistics for 'Guideline36Winter_Autosizing.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 7 warnings info: 0 errors