(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring_res.mat --stripRoot --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_fmu --startTime=7.344e+06 --stopTime=7.776e+06 --stepSize=40.6665 --mode=me --timeout=450 --tolerance=1e-07 ../Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring (model exchange) - fmiVersion: 2.0 - startTime : 7344000.000000 - stopTime : 7776000.000000 - tolerance : 1e-07 - stepSize : 40.6665 LOG_STDOUT | warning | The nominal value of flo.cor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.wes.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.nor.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.eas.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.sou.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. LOG_STDOUT | warning | The nominal value of flo.att.vol.m is 0, but it must be nonzero and finite. The solvers use 1.0 instead. EnergyPlus Starting EnergyPlus, Version 24.2.0-638b8408fd (No OpenGL), YMD=2026.11.17 07:35 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 03/27/2006 for SPAWN-RUNPERIOD info: maximum step size for 'Guideline36Spring.root': 40.666500 info: Result file: ../Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring_res.mat (bufferSize=10) info: Parameter Guideline36Spring.flo.att.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.att.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.cor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.cor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.eas.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.eas.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.epwName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.idfName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.nor.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.nor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.sou.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.sou.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.weaName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.wes.hvacSystemName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.flo.wes.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter Guideline36Spring.weaDat.filNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[1].ala.not2.y), hvac.conVAV[1].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[2].ala.not1.y), hvac.conVAV[2].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[2].ala.not2.y), hvac.conVAV[2].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[3].ala.not2.y), hvac.conVAV[3].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[4].ala.not1.y), hvac.conVAV[4].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[4].ala.not2.y), hvac.conVAV[4].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7367700.000000 | | | | ((hvac.conVAV[5].ala.not2.y), hvac.conVAV[5].ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5753: Invalid root: (-0.512332)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5763: Invalid root: (-0.512332)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5802: Invalid root: (-0.512332)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5812: Invalid root: (-0.512332)^(-1.25) error: [fmi2logger] [fmi2Error] Guideline36Spring/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "Guideline36Spring.root.Guideline36Spring" LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_NLS | error | residualFunc23455: Iteration variable `ò© ` is nan. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 7.54281e+06. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_NLS | error | residualFunc23455: Iteration variable `ò© ` is nan. LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_NLS | error | residualFunc23455: Iteration variable `ò© ` is nan. LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_ASSERT | info | The following assertion has been violated at time 7542809.710072 LOG_NLS | error | residualFunc23455: Iteration variable `ò© ` is nan. LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5753: Invalid root: (-5.81442)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5763: Invalid root: (-5.81442)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5802: Invalid root: (-5.81442)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5812: Invalid root: (-5.81442)^(-1.25) error: [fmi2logger] [fmi2Error] Guideline36Spring/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "Guideline36Spring.root.Guideline36Spring" LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5753: Invalid root: (-1.46899)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5763: Invalid root: (-1.46899)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5802: Invalid root: (-1.46899)^(-1.25) LOG_ASSERT | debug | /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring/773.fmutmp/sources/Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_Guideline36Spring_functions.c:5812: Invalid root: (-1.46899)^(-1.25) error: [fmi2logger] [fmi2Error] Guideline36Spring/logFmi2Call: fmi2GetDerivatives: terminated by an assertion. error: [getDerivatives] fmi2_getDerivatives failed for FMU "Guideline36Spring.root.Guideline36Spring" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 15.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 7625100.000000 | | | | ((hvac.conVAV[5].ala.not1.y), hvac.conVAV[5].ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." Writing final SQL reports EnergyPlus Run Time=00hr 00min 17.09sec EnergyPlus Completed Successfully. info: Final Statistics for 'Guideline36Spring.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 6 errors