/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_HeatPumpRadiantHeatingGroundHeatTransfer_fmu --startTime=0 --stopTime=172800 --stepSize=69.12 --timeout=400 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_HeatPumpRadiantHeatingGroundHeatTransfer.fmu LOG_STDOUT | info | Using sparse solver for linear system 30, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | Using sparse solver for linear system 64, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_24_2_0.UsersGuide.Installation LOG_ASSERT | debug | Solving non-linear system 4873 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. error: [fmi2logger] [fmi2Error] 0001_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_HeatPumpRadiantHeatingGroundHeatTransfer/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SingleFamilyHouse_HeatPumpRadiantHeatingGroundHeatTransfer" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 0 warnings info: 4 errors