/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmu
warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input
warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input
info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2"
info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2"
info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/model-tl2dkk5o"
info: *** FMU Simulation Info ***
- model: model (model exchange)
- path: Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmu
- startTime: 0.000000
- stopTime: 3600.000000
- tolerance: 0.000001
- stepSize: 1.440000
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Using pre-compiled FMU /tmp/fmi4c_bfYvfe/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Resources/src/ThermalZones/EnergyPlus/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
info: maximum step size for 'model.root': 1.440000
info: Result file: model_res.mat (bufferSize=10)
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.epwName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.idfName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_latest_Buildings_ThermalZones_EnergyPlus_24_2_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.zoneName will not be stored in the result file, because the signal type is not supported
info: Final Statistics for 'model.root':
NumSteps = 45 NumRhsEvals = 46 NumLinSolvSetups = 7
NumNonlinSolvIters = 45 NumNonlinSolvConvFails = 0 NumErrTestFails = 0
info: 2 warnings
info: 0 errors