/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Validation_Controller_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Validation_Controller.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller/model-yscjsor0" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Validation.Controller" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Validation_Controller.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120:3-125:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((dedLoc.yPumSpe >= max(dedLoc.pumSpeLocDp.minPumSpe, 0.0) and dedLoc.yPumSpe <= min(dedLoc.pumSpeLocDp.maxPumSpe, 1.0))) --> "Variable violating min/max constraint: max(dedLoc.pumSpeLocDp.minPumSpe, 0.0) <= dedLoc.yPumSpe <= min(dedLoc.pumSpeLocDp.maxPumSpe, 1.0), has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120:3-125:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((dedNoLoc.yPumSpe >= max(dedNoLoc.pumSpeRemDp.minPumSpe, 0.0) and dedNoLoc.yPumSpe <= min(dedNoLoc.pumSpeRemDp.maxPumSpe, 1.0))) --> "Variable violating min/max constraint: max(dedNoLoc.pumSpeRemDp.minPumSpe, 0.0) <= dedNoLoc.yPumSpe <= min(dedNoLoc.pumSpeRemDp.maxPumSpe, 1.0), has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Controller.mo:120:3-125:58:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((heaNoLoc.yPumSpe >= max(heaNoLoc.pumSpeRemDp.minPumSpe, 0.0) and heaNoLoc.yPumSpe <= min(heaNoLoc.pumSpeRemDp.maxPumSpe, 1.0))) --> "Variable violating min/max constraint: max(heaNoLoc.pumSpeRemDp.minPumSpe, 0.0) <= heaNoLoc.yPumSpe <= min(heaNoLoc.pumSpeRemDp.maxPumSpe, 1.0), has value: 0" info: maximum step size for 'model.root': 1.440000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 250 NumRhsEvals = 286 NumLinSolvSetups = 38 NumNonlinSolvIters = 285 NumNonlinSolvConvFails = 2 NumErrTestFails = 7 info: 2 warnings info: 0 errors