/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Subsequences_Validation_Speed_primary_remoteDp_fmu --startTime=0 --stopTime=10 --stepSize=0.004 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Subsequences_Validation_Speed_primary_remoteDp.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Subsequences.Validation.Speed_primary_remoteDp" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Subsequences.Validation.Speed_primary_remoteDp" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Subsequences.Validation.Speed_primary_remoteDp/model-tokly4by" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Controls.OBC.ASHRAE.G36.Plants.Chillers.Pumps.ChilledWater.Subsequences.Validation.Speed_primary_remoteDp" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Controls_OBC_ASHRAE_G36_Plants_Chillers_Pumps_ChilledWater_Subsequences_Validation_Speed_primary_remoteDp.fmu - startTime: 0.000000 - stopTime: 10.000000 - tolerance: 0.000001 - stepSize: 0.004000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/ASHRAE/G36/Plants/Chillers/Pumps/ChilledWater/Subsequences/Speed_primary_remoteDp.mo:45:3-50:56:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((chiPumSpe.yChiWatPumSpe >= chiPumSpe.minPumSpe and chiPumSpe.yChiWatPumSpe <= chiPumSpe.maxPumSpe)) --> "Variable violating min/max constraint: chiPumSpe.minPumSpe <= chiPumSpe.yChiWatPumSpe <= chiPumSpe.maxPumSpe, has value: 0" info: maximum step size for 'model.root': 0.004000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors