/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Fluid.HeatExchangers.DXCoils.WaterCooled.Validation.VariableSpeedEnergyPlus_res.mat --tempDir=temp_Buildings_9_Buildings_Fluid_HeatExchangers_DXCoils_WaterCooled_Validation_VariableSpeedEnergyPlus_fmu --startTime=0 --stopTime=86400 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Fluid_HeatExchangers_DXCoils_WaterCooled_Validation_VariableSpeedEnergyPlus.fmu LOG_NLS | error | residualFunc1210: Iteration variable `ͺ)πό` is inf or nan. LOG_ASSERT | debug | residualFunc1210 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc1210: Iteration variable `(null)` is inf or nan. LOG_ASSERT | debug | residualFunc1210 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc1210: Iteration variable `ͺ)πό` is inf or nan. LOG_ASSERT | debug | residualFunc1210 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_NLS | error | residualFunc1210: Iteration variable `ͺ)πό` is inf or nan. LOG_ASSERT | debug | residualFunc1210 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((varSpeDX.eva.eva.nomVal.gamma <= varSpeDX.eva.eva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.346977, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.462462 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00571197 - 0.00634552 = -0.000633544 | | | | QLat_flow_nominal = -1689.5 | | | | " info: maximum step size for 'model.root': 172.800000 info: Result file: Buildings_9_Buildings.Fluid.HeatExchangers.DXCoils.WaterCooled.Validation.VariableSpeedEnergyPlus_res.mat (bufferSize=1) info: Variable model.root.Buildings_9_Buildings_Fluid_HeatExchangers_DXCoils_WaterCooled_Validation_VariableSpeedEnergyPlus.varSpeDX.eva.substanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/PartialCoolingCapacity.mo:126:7-139:38:writable] | | | | The following assertion has been violated at time 25372.800000 | | | | ((not (varSpeDX.eva.dxCoo.TEvaIn > varSpeDX.eva.dxCoo.dryCoi.cooCap.sta[varSpeDX.eva.dxCoo.dryCoi.cooCap.stage].perCur.TEvaInMax or varSpeDX.eva.dxCoo.TEvaIn < varSpeDX.eva.dxCoo.dryCoi.cooCap.sta[varSpeDX.eva.dxCoo.dryCoi.cooCap.stage].perCur.TEvaInMin))) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 25372.8. | | | | stage = 1 | | | | TEvaInMin = 283.15 Kelvin (10 degC) | | | | TEvaIn = 299.077 Kelvin (25.9269 degC) | | | | TEvaInMax = 298.75 Kelvin (25.6 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage."