/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.EvaporationPulse_res.mat --tempDir=temp_Buildings_9_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Fluid_HeatExchangers_DXCoils_BaseClasses_Examples_EvaporationPulse.fmu LOG_NLS | error | residualFunc43: Iteration variable `` is inf or nan. LOG_ASSERT | debug | residualFunc43 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_NLS | error | residualFunc83: Iteration variable `` is inf or nan. LOG_ASSERT | debug | residualFunc83 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed during initialization. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((evaSho.nomVal.gamma <= evaSho.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 1.00359, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.497018 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00614376 - 0.00715296 = -0.0010092 | | | | QLat_flow_nominal = -1000 | | | | " LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/HeatExchangers/DXCoils/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((evaNor.nomVal.gamma <= evaNor.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 1.00359, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.497018 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00614376 - 0.00715296 = -0.0010092 | | | | QLat_flow_nominal = -1000 | | | | " info: maximum step size for 'model.root': 14.400000 info: Result file: Buildings_9_Buildings.Fluid.HeatExchangers.DXCoils.BaseClasses.Examples.EvaporationPulse_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 74 NumRhsEvals = 80 NumLinSolvSetups = 12 NumNonlinSolvIters = 79 NumNonlinSolvConvFails = 0 NumErrTestFails = 0