(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Winter_fmu --startTime=432000 --stopTime=864000 --stepSize=172.8 --mode=me --timeout=240 --tolerance=1e-07 ../Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Winter.fmu) info: *** FMU Simulation Info *** - model : Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.ASHRAE2006Winter (model exchange) - fmiVersion: 2.0 - startTime : 432000.000000 - stopTime : 864000.000000 - tolerance : 1e-07 - stepSize : 172.8 EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2026.11.17 06:13 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/06/2006 for SPAWN-RUNPERIOD info: maximum step size for 'ASHRAE2006Winter.root': 172.800000 info: Result file: Buildings_13_Buildings_ThermalZones_EnergyPlus_24_2_0_Examples_SmallOffice_ASHRAE2006Winter_res.mat (bufferSize=10) info: Parameter ASHRAE2006Winter.flo.att.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.cor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.eas.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.epwName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.idfName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.nor.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.sou.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.weaName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.flo.wes.zoneName will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.hvac.conVAV[1].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.hvac.conVAV[2].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.hvac.conVAV[3].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.hvac.conVAV[4].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.hvac.conVAV[5].assMes.message will not be stored in the result file, because the signal type is not supported info: Parameter ASHRAE2006Winter.weaDat.filNam will not be stored in the result file, because the signal type is not supported Writing final SQL reports EnergyPlus Run Time=00hr 00min 4.04sec EnergyPlus Completed Successfully. info: Final Statistics for 'ASHRAE2006Winter.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0