(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Fluid_DXSystems_Cooling_AirSource_Validation_SingleSpeedPLR_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --mode=me --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Fluid_DXSystems_Cooling_AirSource_Validation_SingleSpeedPLR.fmu) info: *** FMU Simulation Info *** - model : Buildings.Fluid.DXSystems.Cooling.AirSource.Validation.SingleSpeedPLR (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 86400.000000 - tolerance : 1e-06 - stepSize : 34.56 warning: [fmi2Warning] SingleSpeedPLR/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185: The following assertion has been violated during initialization at time 0.000000 ((sinSpeDX.watVapEva.nomVal.gamma <= sinSpeDX.watVapEva.gammaMax), sinSpeDX.watVapEva.nomVal.gamma=1.5, sinSpeDX.watVapEva.gammaMax=0.3472586957788176) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. Instead of gamma = 1.5, a value of 0.347259, which corresponds to a mass transfer effectiveness of 0.8, will be used. Coil nominal performance data are: nomVal.m_flow_nominal = 1.72 dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00562847 - 0.00620134 = -0.000572874 QLat_flow_nominal = -5677.29 info: maximum step size for 'SingleSpeedPLR.root': 34.560000 info: Result file: Buildings_13_Buildings_Fluid_DXSystems_Cooling_AirSource_Validation_SingleSpeedPLR_res.mat (bufferSize=10) info: Parameter SingleSpeedPLR.onOff.combiTimeTable.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter SingleSpeedPLR.onOff.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter SingleSpeedPLR.onOff.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((not (sinSpeDX.dxCoi.TEvaIn > sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMax or sinSpeDX.dxCoi.TEvaIn < sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMin)), sinSpeDX.dxCoi.TEvaIn=297.23651629, sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMax=297.03889, sinSpeDX.dxCoi.dryCoi.coiCap.sta[1].perCur.TEvaInMin=285.92778) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 25200. | | | | stage = 1 | | | | TEvaInMin = 285.928 Kelvin (12.7778 degC) | | | | TEvaIn = 297.237 Kelvin (24.0865 degC) | | | | TEvaInMax = 297.039 Kelvin (23.8889 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." info: Final Statistics for 'SingleSpeedPLR.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 1 warnings info: 0 errors