(cd run_OMSimulator && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --mode=me --timeout=240 --tolerance=1e-06 ../Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.fmu) info: *** FMU Simulation Info *** - model : Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms (model exchange) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 7200.000000 - tolerance : 1e-06 - stepSize : 2.88 warning: [fmi2Warning] Alarms/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated during initialization at time 0.000000 ((ala.not10.y), ala.not10.y=false) --> "Warning: fan has been commanded ON but still OFF." info: model doesn't contain any continuous state info: maximum step size for 'Alarms.root': 2.880000 info: Result file: Buildings_13_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms_res.mat (bufferSize=10) info: Variable Alarms.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes5.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes6.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes7.message will not be stored in the result file, because the signal type is not supported info: Variable Alarms.ala.assMes8.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 850.000000 | | | | ((ala.not7.y), ala.not7.y=false) --> "Warning: discharge air temperature is 8 degC less than the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 956.640000 | | | | ((ala.not2.y), ala.not2.y=false) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 2701.920000 | | | | ((ala.not1.y), ala.not1.y=false) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 3765.000000 | | | | ((ala.not11.y), ala.not11.y=false) --> "Warning: fan has been commanded OFF but still ON." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 4350.000000 | | | | ((not ala.truDel3.y), ala.truDel3.y=true) --> "Warning: the damper is leaking." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 6225.000000 | | | | ((not ala.truDel2.y), ala.truDel2.y=true) --> "Warning: airflow sensor should be calibrated." info: Final Statistics for 'Alarms.root': NumSteps = 0 NumRhsEvals = 0 NumLinSolvSetups = 0 NumNonlinSolvIters = 0 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 1 warnings info: 0 errors