/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_res.mat --tempDir=temp_Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_fmu --startTime=0 --stopTime=345600 --stepSize=125.445 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage/model-qcjq1zza" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.fmu - startTime: 0.000000 - stopTime: 345600.000000 - tolerance: 0.000001 - stepSize: 125.445000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/BaseClasses/PartialEffectivenessNTU.mo:112:5-117:36:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pla.hexCoo.Q_flow_nominal / (300.05 - pla.hexCoo.T_a2_nominal) >= 0.0)) --> "In AllElectricCWStorage.pla.hexCoo: Q_flow_nominal is defined with the wrong sign. By convention, a positive value describes a heat flow from Medium1 to Medium2. The parameter T_a1_nominal should then be larger than T_a2_nominal.Future version of this library might enforce this convention and throw an error." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumChiWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -9.64889e-45" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumHeaWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -1.09987e-42" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatCon.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.etaHyd, has value: -4.29028e-47" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatEva.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -2.67136e-40" info: maximum step size for 'model.root': 125.445000 info: Result file: Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_res.mat (bufferSize=1) info: Parameter model.root.Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.pla.heaPum.heaPum.aleMes.message will not be stored in the result file, because the signal type is not supported LOG_NLS | error | residualFunc14672: Iteration variable `(null)` is inf or nan. LOG_ASSERT | debug | residualFunc14672 failed at time=14400. | | | | For more information please use -lv LOG_NLS. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 14400. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V