/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Utilities.Psychrometrics.Functions.BaseClasses.Examples.InverseDewPointTemperatureDerivativeCheck_amb_res.mat --tempDir=temp_Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb_fmu --startTime=-1 --stopTime=1 --timeout=400 --tolerance=1e-09 Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb.fmu info: maximum step size for 'model.root': 0.004000 info: Result file: Buildings_11_Buildings.Utilities.Psychrometrics.Functions.BaseClasses.Examples.InverseDewPointTemperatureDerivativeCheck_amb_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Utilities/Psychrometrics/Functions/BaseClasses/Examples/InverseDewPointTemperatureDerivativeCheck_amb.mo:17:3-17:100:writable] | | | | The following assertion has been violated at time -0.996000 | | | | ((abs(err) < 0.01)) --> "Derivative implementation has an error or solver tolerance is too low." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Utilities.Psychrometrics.Functions.BaseClasses.Examples.InverseDewPointTemperatureDerivativeCheck_amb/temp_Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb_fmu/model-chp6z46t/temp/0001_Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb" warning: Bad return code at time -0.996000 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Utilities/Psychrometrics/Functions/BaseClasses/Examples/InverseDewPointTemperatureDerivativeCheck_amb.mo:17:3-17:100:writable] | | | | The following assertion has been violated at time -0.996000 | | | | ((abs(err) < 0.01)) --> "Derivative implementation has an error or solver tolerance is too low." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Utilities.Psychrometrics.Functions.BaseClasses.Examples.InverseDewPointTemperatureDerivativeCheck_amb/temp_Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb_fmu/model-chp6z46t/temp/0001_Buildings_11_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_InverseDewPointTemperatureDerivativeCheck_amb (logFmi2Call): fmi2GetReal: terminated by an assertion. error: [updateSignals] failed to fetch variable y info: Final Statistics for 'model.root': NumSteps = 2 NumRhsEvals = 3 NumLinSolvSetups = 2 NumNonlinSolvIters = 2 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 1 warnings info: 4 errors