/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow_res.mat --tempDir=temp_Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow_fmu --startTime=0 --stopTime=86400 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/ThermalZones/Detailed/BaseClasses/InfraredRadiationExchange.mo:70:3-74:37:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((roo.irRadExc.G[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= roo.irRadExc.G[1], has value: -4187.66" info: maximum step size for 'model.root': 172.800000 info: Result file: Buildings_11_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow_res.mat (bufferSize=1) info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.air.datConBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.air.datConExt[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.air.datConExtWin[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.air.datConPar[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.air.surBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.bouConExt.conPar[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.datConBou[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.datConExt[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.datConExtWin[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.datConPar[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadExc.datConBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadExc.datConExt[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadExc.datConExtWin[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadExc.datConPar[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadExc.surBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadGai.datConBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadGai.datConExt[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadGai.datConExtWin[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadGai.datConPar[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.irRadGai.surBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.radTem.datConBou[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.radTem.datConExt[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.radTem.datConExtWin[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.radTem.datConPar[1].name will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.radTem.surBou[1].name will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_SampledModel_OnlyExteriorWallNoWindow.roo.surBou[1].name will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 7 NumRhsEvals = 9 NumLinSolvSetups = 7 NumNonlinSolvIters = 8 NumNonlinSolvConvFails = 0 NumErrTestFails = 0