/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.HeatingOnly_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly_fmu --startTime=0 --stopTime=172800 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly.fmu info: maximum step size for 'model.root': 345.600000 info: Result file: Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.HeatingOnly_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:62:5-63:122:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((noEvent(beaCooHea.conHea.hex.vol.dynBal.medium.T >= 272.15))) --> "In HeatingOnly.beaCooHea.conHea.hex.vol.dynBal.medium: Temperature T = 255.559 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.HeatingOnly/temp_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly_fmu/model-zvg78iz2/temp/0001_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:62:5-63:122:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((noEvent(beaCooHea.conHea.hex.vol.dynBal.medium.T >= 272.15))) --> "In HeatingOnly.beaCooHea.conHea.hex.vol.dynBal.medium: Temperature T = 256.726 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.HeatingOnly/temp_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly_fmu/model-zvg78iz2/temp/0001_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_HeatingOnly (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable vol.use_C_flow info: Final Statistics for 'model.root': NumSteps = 135 NumRhsEvals = 194 NumLinSolvSetups = 42 NumNonlinSolvIters = 193 NumNonlinSolvConvFails = 0 NumErrTestFails = 12 info: 0 warnings info: 4 errors