/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.CoolingAndHeating_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating_fmu --startTime=0 --stopTime=172800 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating.fmu info: maximum step size for 'model.root': 345.600000 info: Result file: Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.CoolingAndHeating_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:62:5-63:122:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((noEvent(beaCooHea.conHea.hex.vol.dynBal.medium.T >= 272.15))) --> "In CoolingAndHeating.beaCooHea.conHea.hex.vol.dynBal.medium: Temperature T = 261.701 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.CoolingAndHeating/temp_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating_fmu/model-yd7ovwsx/temp/0001_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:62:5-63:122:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((noEvent(beaCooHea.conHea.hex.vol.dynBal.medium.T >= 272.15))) --> "In CoolingAndHeating.beaCooHea.conHea.hex.vol.dynBal.medium: Temperature T = 264.48 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatExchangers.ActiveBeams.Examples.CoolingAndHeating/temp_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating_fmu/model-yd7ovwsx/temp/0001_Buildings_11_Buildings_Fluid_HeatExchangers_ActiveBeams_Examples_CoolingAndHeating (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable vol.use_C_flow info: Final Statistics for 'model.root': NumSteps = 175 NumRhsEvals = 257 NumLinSolvSetups = 51 NumNonlinSolvIters = 256 NumNonlinSolvConvFails = 0 NumErrTestFails = 17 info: 0 warnings info: 4 errors