/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.DXSystems.BaseClasses.Examples.DryCoil_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_DXSystems_BaseClasses_Examples_DryCoil_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_DXSystems_BaseClasses_Examples_DryCoil.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.DXSystems.BaseClasses.Examples.DryCoil" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.DXSystems.BaseClasses.Examples.DryCoil" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.DXSystems.BaseClasses.Examples.DryCoil/model-sfelk2jr" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_Fluid_DXSystems_BaseClasses_Examples_DryCoil.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 info: model doesn't contain any continuous state info: maximum step size for 'model.root': 1.440000 info: Result file: Buildings_11_Buildings.Fluid.DXSystems.BaseClasses.Examples.DryCoil_res.mat (bufferSize=1) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 1200.000000 | | | | ((not (TEvaIn.y > dryCoi.coiCap.sta[dryCoi.coiCap.stage].perCur.TEvaInMax or TEvaIn.y < dryCoi.coiCap.sta[dryCoi.coiCap.stage].perCur.TEvaInMin))) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 1200. | | | | stage = 1 | | | | TEvaInMin = 285.928 Kelvin (12.7778 degC) | | | | TEvaIn = 302.15 Kelvin (29 degC) | | | | TEvaInMax = 297.039 Kelvin (23.8889 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." info: Final Statistics for 'model.root': NumSteps = 420 NumRhsEvals = 421 NumLinSolvSetups = 25 NumNonlinSolvIters = 420 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors