/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.CHPs.Validation.ThermalFollowing_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing_fmu --startTime=0 --stopTime=10000 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.fmu LOG_STDOUT | info | ... loading "tab1" from "/tmp/fmi4c_VkzggK/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Resources/Data/Fluid/CHPs/Validation/MicroCogeneration.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((theFolNeg.opeMod.assWatMas.nand.y)) --> "Water flow rate is lower than the minimum!" info: maximum step size for 'model.root': 20.000000 info: Result file: Buildings_11_Buildings.Fluid.CHPs.Validation.ThermalFollowing_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.avaSig.combiTimeTable.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFol.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.assWatTem.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.fil.assPow.assMesDP.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.theFolNeg.fil.assPow.assMesP.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_11_Buildings_Fluid_CHPs_Validation_ThermalFollowing.valDat.tableName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 3960 NumRhsEvals = 5892 NumLinSolvSetups = 1365 NumNonlinSolvIters = 5858 NumNonlinSolvConvFails = 0 NumErrTestFails = 447