/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.DHC.Plants.Cooling.Examples.ElectricChillerParallel_res.mat --tempDir=temp_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel_fmu --startTime=0 --stopTime=86400 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel.fmu info: maximum step size for 'model.root': 172.800000 info: Result file: Buildings_11_Buildings.DHC.Plants.Cooling.Examples.ElectricChillerParallel_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:68:5-68:152:writable] | | | | The following assertion has been violated at time 345.600000 | | | | ((noEvent(pla.mulChiSys.chi[2].vol2.p >= 0.0))) --> "Pressure (= -58142.2 Pa) of medium "Buildings.Media.Water" is negative | | | | (Temperature = 293.15 K)" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Cooling.Examples.ElectricChillerParallel/temp_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel_fmu/model-soy8gauk/temp/0001_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pla.pumCW.swi[2].u2 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 691.200000 | | | | ((noEvent(vol.dynBal.medium.T <= 403.15))) --> "In ElectricChillerParallel.vol.dynBal.medium: Temperature T = 408.164 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Cooling.Examples.ElectricChillerParallel/temp_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel_fmu/model-soy8gauk/temp/0001_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStepCVODE] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel" warning: Bad return code at time 691.200000 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Water.mo:65:5-66:122:writable] | | | | The following assertion has been violated at time 691.200000 | | | | ((noEvent(vol.dynBal.medium.T <= 403.15))) --> "In ElectricChillerParallel.vol.dynBal.medium: Temperature T = 408.164 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "Buildings.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Cooling.Examples.ElectricChillerParallel/temp_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel_fmu/model-soy8gauk/temp/0001_Buildings_11_Buildings_DHC_Plants_Cooling_Examples_ElectricChillerParallel (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pla.pumCW.swi[2].u2 info: Final Statistics for 'model.root': NumSteps = 142 NumRhsEvals = 215 NumLinSolvSetups = 46 NumNonlinSolvIters = 214 NumNonlinSolvConvFails = 0 NumErrTestFails = 14 info: 1 warnings info: 6 errors