/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Subsequences.Validation.Alarms_res.mat --tempDir=temp_Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Subsequences_Validation_Alarms.fmu info: model doesn't contain any continuous state info: Result file: Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctMixConDischargeSensor.Subsequences.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Subsequences_Validation_Alarms.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Subsequences_Validation_Alarms.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Subsequences_Validation_Alarms.ala.assMes6.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctMixConDischargeSensor_Subsequences_Validation_Alarms.ala.assMes7.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 1150.000021 | | | | ((ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 4050.000110 | | | | ((ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 4350.000037 | | | | ((not ala.truDel7.y)) --> "Warning: the cold-duct or hot-dcut damper is leaking." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 6225.000018 | | | | ((not ala.truDel6.y)) --> "Warning: airflow sensor should be calibrated."