/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_fmu --startTime=1.0368e+07 --stopTime=1.07136e+07 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.fmu LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage/temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_fmu/model-ydr8dnh3/temp/0001_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not (pump1.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump1.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.per.haveWMot_nominal or not (pump1.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump1.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not (pump2.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump2.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.per.haveWMot_nominal or not (pump2.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump2.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not senTem1.warnAboutOnePortConnection)) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." info: maximum step size for 'model.root': 691.200000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 1.04115e+07, mxstep steps taken before reaching tout. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -1 [CVODE ERROR] CVode At t = 1.04418e+07, mxstep steps taken before reaching tout. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -1 error: [operator()] Timeout occurred during simulation info: 0 warnings info: 3 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage/temp_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage_fmu/model-ydr8dnh3/temp/0001_BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [updateInputs] fmi2_setTime failed for FMU "model.root.BuildingSystems_BuildingSystems_Technologies_SolarThermal_Examples_BigCollectorInstallationWithStorage"