/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage_fmu --startTime=0 --stopTime=20000 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in CogenerationUnitWithStorage.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in CogenerationUnitWithStorage.pump: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in CogenerationUnitWithStorage.pump: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." info: maximum step size for 'model.root': 40.000000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage.CHP.etaEl.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage.CHP.etaEl.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage.CHP.etaTh.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage.CHP.etaTh.tableName will not be stored in the result file, because the signal type is not supported error: [getReal] getReal returned NAN error: [updateSignals] failed to fetch variable CHP.vol.heatPort.Q_flow [CVODE ERROR] CVode At t = 17200 and h = 1e-12, the corrector convergence test failed repeatedly or with |h| = hmin. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -4 LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Media/Water.mo:62:5-63:128:writable] | | | | The following assertion has been violated at time 17200.000000 | | | | ((noEvent(storage.vol[1].dynBal.medium.T >= 272.15))) --> "In CogenerationUnitWithStorage.storage.vol[1].dynBal.medium: Temperature T = -nan K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.Cogeneration.Examples.CogenerationUnitWithStorage/temp_BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage_fmu/model-x8tpmj8g/temp/0001_BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Media/Water.mo:62:5-63:128:writable] | | | | The following assertion has been violated at time 17200.000000 | | | | ((noEvent(CHP.vol.dynBal.medium.T >= 272.15))) --> "In CogenerationUnitWithStorage.CHP.vol.dynBal.medium: Temperature T = -nan K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "BuildingSystems.Media.Water"." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.Cogeneration.Examples.CogenerationUnitWithStorage/temp_BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage_fmu/model-x8tpmj8g/temp/0001_BuildingSystems_BuildingSystems_Technologies_Cogeneration_Examples_CogenerationUnitWithStorage (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable booleanToReal2.u info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 56 NumLinSolvSetups = 11 NumNonlinSolvIters = 55 NumNonlinSolvConvFails = 11 NumErrTestFails = 0 info: 0 warnings info: 7 errors