Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(BuildingSystems.Buildings.Examples.Building1Zone0D,fileNamePrefix="BuildingSystems_BuildingSystems_Buildings_Examples_Building1Zone0D",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildingSystems.Buildings.Examples.Building1Zone0D,fileNamePrefix="BuildingSystems_BuildingSystems_Buildings_Examples_Building1Zone0D",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00625/0.00625, allocations: 102 kB / 15.73 MB, free: 6.039 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001301/0.001301, allocations: 194.5 kB / 16.67 MB, free: 5.961 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.346/1.346, allocations: 222.9 MB / 240.4 MB, free: 15.14 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.002359/0.002359, allocations: 296.8 kB / 290.8 MB, free: 14.45 MB / 238.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.9241/0.9241, allocations: 169.2 MB / 0.4983 GB, free: 4.453 MB / 382.1 MB Notification: Performance of FrontEnd - loaded program: time 0.00331/0.003311, allocations: 99.84 kB / 0.6809 GB, free: 7.516 MB / 494.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4913/0.4946, allocations: 86.97 MB / 0.7659 GB, free: 3.914 MB / 0.5294 GB Notification: Performance of NFInst.instantiate(BuildingSystems.Buildings.Examples.Building1Zone0D): time 0.763/1.258, allocations: 302.8 MB / 1.062 GB, free: 396 kB / 0.7169 GB Notification: Performance of NFInst.instExpressions: time 0.04914/1.307, allocations: 27.46 MB / 1.088 GB, free: 8.051 MB / 0.7325 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01413/1.321, allocations: 251.2 kB / 1.089 GB, free: 8.051 MB / 0.7325 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:109:3-111:146:writable] Warning: Connector toAmbienceSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:112:3-114:149:writable] Warning: Connector toAmbienceAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToSolids.mo:11:3-13:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ZoneTemplateGeneral.mo:63:3-67:55:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/RadiationDistribution.mo:13:3-15:72:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/AirvolumeGeneral.mo:40:3-41:97:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:52:3-55:54:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:56:3-59:53:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/SolarRadiationTransformers/SolarRadiationTransformerGeneral.mo:25:3-27:116:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:109:3-111:146:writable] Warning: Connector toAmbienceSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:112:3-114:149:writable] Warning: Connector toAmbienceAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToSolids.mo:11:3-13:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ZoneTemplateGeneral.mo:63:3-67:55:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/RadiationDistribution.mo:13:3-15:72:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/AirvolumeGeneral.mo:40:3-41:97:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:52:3-55:54:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:56:3-59:53:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/SolarRadiationTransformers/SolarRadiationTransformerGeneral.mo:25:3-27:116:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.00928/1.33, allocations: 2.611 MB / 1.091 GB, free: 6.949 MB / 0.7325 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Airvolumes/AirvolumeMixed.mo:70:5-70:12:writable] Warning: Conditional component 'air' is used in a non-connect context. Notification: Performance of NFTyping.typeBindings: time 0.02115/1.352, allocations: 6.429 MB / 1.097 GB, free: 2.895 MB / 0.7325 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeClassSections: time 0.01244/1.364, allocations: 4.433 MB / 1.102 GB, free: 14.74 MB / 0.7481 GB Notification: Performance of NFFlatten.flatten: time 0.02929/1.393, allocations: 21.42 MB / 1.123 GB, free: 9.664 MB / 0.7637 GB Notification: Performance of NFFlatten.resolveConnections: time 0.03656/1.43, allocations: 26.44 MB / 1.148 GB, free: 15.36 MB / 0.795 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01906/1.449, allocations: 9.985 MB / 1.158 GB, free: 5.582 MB / 0.795 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01881/1.468, allocations: 11.25 MB / 1.169 GB, free: 10.63 MB / 0.8106 GB Notification: Performance of NFPackage.collectConstants: time 0.008369/1.476, allocations: 3.066 MB / 1.172 GB, free: 7.566 MB / 0.8106 GB Notification: Performance of NFFlatten.collectFunctions: time 0.01452/1.491, allocations: 5.505 MB / 1.178 GB, free: 2.32 MB / 0.8106 GB Notification: Performance of NFScalarize.scalarize: time 0.01035/1.501, allocations: 6.525 MB / 1.184 GB, free: 11.82 MB / 0.8262 GB Notification: Performance of NFVerifyModel.verify: time 0.02086/1.522, allocations: 11.22 MB / 1.195 GB, free: 0.5977 MB / 0.8262 GB Notification: Performance of NFConvertDAE.convert: time 0.04165/1.564, allocations: 35.39 MB / 1.229 GB, free: 13.69 MB / 0.8731 GB Notification: Performance of FrontEnd - DAE generated: time 8.916e-06/1.564, allocations: 0 / 1.229 GB, free: 13.69 MB / 0.8731 GB Notification: Performance of FrontEnd: time 2.084e-06/1.564, allocations: 0 / 1.229 GB, free: 13.69 MB / 0.8731 GB Notification: Performance of Transformations before backend: time 0.001183/1.565, allocations: 0 / 1.229 GB, free: 13.69 MB / 0.8731 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 4400 * Number of variables: 4400 Notification: Performance of Generate backend data structure: time 0.05606/1.621, allocations: 17.9 MB / 1.247 GB, free: 11.62 MB / 0.8887 GB Notification: Performance of prepare preOptimizeDAE: time 5.49e-05/1.621, allocations: 16.02 kB / 1.247 GB, free: 11.61 MB / 0.8887 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.009338/1.631, allocations: 2.277 MB / 1.249 GB, free: 9.32 MB / 0.8887 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02157/1.652, allocations: 3.419 MB / 1.253 GB, free: 5.879 MB / 0.8887 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0274/1.68, allocations: 10.13 MB / 1.262 GB, free: 11.66 MB / 0.9044 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001466/1.681, allocations: 1.552 MB / 1.264 GB, free: 10.03 MB / 0.9044 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.006228/1.687, allocations: 1.594 MB / 1.266 GB, free: 8.434 MB / 0.9044 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.07169/1.759, allocations: 25.93 MB / 1.291 GB, free: 13.98 MB / 0.9356 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0006014/1.76, allocations: 27.66 kB / 1.291 GB, free: 13.95 MB / 0.9356 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.005729/1.765, allocations: 0.6679 MB / 1.292 GB, free: 13.29 MB / 0.9356 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001939/1.767, allocations: 0.8507 MB / 1.292 GB, free: 12.43 MB / 0.9356 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.05547/1.823, allocations: 22.06 MB / 1.314 GB, free: 6.34 MB / 0.9512 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.5531/2.376, allocations: 84.43 MB / 1.396 GB, free: 319.6 MB / 0.9512 GB Notification: Performance of preOpt comSubExp (simulation): time 0.01399/2.39, allocations: 6.054 MB / 1.402 GB, free: 316.3 MB / 0.9512 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.006239/2.396, allocations: 3.187 MB / 1.405 GB, free: 314.6 MB / 0.9512 GB Notification: Performance of preOpt evalFunc (simulation): time 0.002335/2.399, allocations: 2.449 MB / 1.408 GB, free: 311.8 MB / 0.9512 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.007146/2.406, allocations: 3.436 MB / 1.411 GB, free: 308.8 MB / 0.9512 GB Notification: Performance of pre-optimization done (n=350): time 8.806e-06/2.406, allocations: 0 / 1.411 GB, free: 308.8 MB / 0.9512 GB Notification: Performance of matching and sorting (n=350): time 0.037/2.443, allocations: 12.98 MB / 1.424 GB, free: 295.9 MB / 0.9512 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001348/2.443, allocations: 0.5278 MB / 1.424 GB, free: 295.2 MB / 0.9512 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0223/2.465, allocations: 12.33 MB / 1.436 GB, free: 282.9 MB / 0.9512 GB Notification: Performance of collectPreVariables (initialization): time 0.001227/2.467, allocations: 93.7 kB / 1.436 GB, free: 282.8 MB / 0.9512 GB Notification: Performance of collectInitialEqns (initialization): time 0.006671/2.473, allocations: 7.397 MB / 1.444 GB, free: 275.4 MB / 0.9512 GB Notification: Performance of collectInitialBindings (initialization): time 0.002095/2.476, allocations: 1.257 MB / 1.445 GB, free: 274.1 MB / 0.9512 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.007199/2.483, allocations: 2.023 MB / 1.447 GB, free: 272.1 MB / 0.9512 GB Notification: Performance of setup shared object (initialization): time 4.738e-05/2.483, allocations: 309 kB / 1.447 GB, free: 271.8 MB / 0.9512 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.009496/2.492, allocations: 5.1 MB / 1.452 GB, free: 266.7 MB / 0.9512 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.01107/2.503, allocations: 7.706 MB / 1.46 GB, free: 257.9 MB / 0.9512 GB Notification: Performance of analyzeInitialSystem (initialization): time 6.292/8.795, allocations: 0.9005 GB / 2.36 GB, free: 102.4 MB / 0.9512 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 7.712e-05/8.796, allocations: 27.98 kB / 2.36 GB, free: 102.4 MB / 0.9512 GB Notification: Performance of matching and sorting (n=838) (initialization): time 0.03524/8.831, allocations: 15.91 MB / 2.376 GB, free: 88.29 MB / 0.9512 GB Notification: Performance of prepare postOptimizeDAE: time 0.0003121/8.831, allocations: 314.1 kB / 2.376 GB, free: 87.95 MB / 0.9512 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001321/8.831, allocations: 87.94 kB / 2.376 GB, free: 87.86 MB / 0.9512 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.008102/8.839, allocations: 2.513 MB / 2.379 GB, free: 85.33 MB / 0.9512 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.013/8.852, allocations: 2.656 MB / 2.381 GB, free: 82.67 MB / 0.9512 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02477/8.877, allocations: 30.04 MB / 2.41 GB, free: 51.75 MB / 0.9512 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01316/8.89, allocations: 1.397 MB / 2.412 GB, free: 50.85 MB / 0.9512 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.002226/8.893, allocations: 0.7223 MB / 2.413 GB, free: 50.12 MB / 0.9512 GB Warning: Assuming fixed start value for the following 10 variables: building1.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building1.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building1.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building1.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] building2.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building2.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building2.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building2.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.01816/8.911, allocations: 10.38 MB / 2.423 GB, free: 39.75 MB / 0.9512 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.01086/8.922, allocations: 7.675 MB / 2.43 GB, free: 30.86 MB / 0.9512 GB Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 6.661/15.58, allocations: 0.9004 GB / 3.331 GB, free: 217.9 MB / 0.9512 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 5.963e-05/15.58, allocations: 24 kB / 3.331 GB, free: 217.9 MB / 0.9512 GB Notification: Performance of matching and sorting (n=838) (initialization_lambda0): time 0.03378/15.62, allocations: 15.86 MB / 3.346 GB, free: 205 MB / 0.9512 GB Notification: Performance of prepare postOptimizeDAE: time 0.0003182/15.62, allocations: 310.3 kB / 3.346 GB, free: 204.6 MB / 0.9512 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001156/15.62, allocations: 84 kB / 3.347 GB, free: 204.5 MB / 0.9512 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.007804/15.62, allocations: 2.522 MB / 3.349 GB, free: 202 MB / 0.9512 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01288/15.64, allocations: 2.648 MB / 3.352 GB, free: 199.3 MB / 0.9512 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02421/15.66, allocations: 30.01 MB / 3.381 GB, free: 168.5 MB / 0.9512 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01339/15.68, allocations: 0.8675 MB / 3.382 GB, free: 167.7 MB / 0.9512 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.002445/15.68, allocations: 0.7223 MB / 3.382 GB, free: 167 MB / 0.9512 GB Warning: Assuming fixed start value for the following 10 variables: building1.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building1.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building1.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building1.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] building2.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building2.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building2.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building2.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 386 * Number of states: 0 () * Number of discrete variables: 12 (ambience1.radiation[1].outsidePolarCircle,ambience1.radiation[2].outsidePolarCircle,ambience1.weatherDataReader.weatherData.conTim.tNext,$PRE.ambience1.weatherDataReader.weatherData.conTim.tNext,$whenCondition2,ambience2.radiation[1].outsidePolarCircle,ambience2.radiation[2].outsidePolarCircle,ambience2.weatherDataReader.weatherData.conTim.tNext,$PRE.ambience2.weatherDataReader.weatherData.conTim.tNext,$whenCondition1,building1.zone.coolingLoad.I.local_reset,building1.zone.heatingLoad.I.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (760): * Single equations (assignments): 734 * Array equations: 0 * Algorithm blocks: 6 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 14 * Torn equation systems: 6 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 14 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 6 systems {(5,20), (1,3), (1,3), (1,3), (5,20), (1,3)} Notification: Performance of prepare postOptimizeDAE: time 0.002261/15.68, allocations: 0.7032 MB / 3.383 GB, free: 166.3 MB / 0.9512 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.00235/15.68, allocations: 0.8443 MB / 3.384 GB, free: 165.7 MB / 0.9512 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.02044/15.7, allocations: 9.542 MB / 3.393 GB, free: 156.1 MB / 0.9512 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 4.393e-05/15.7, allocations: 47.94 kB / 3.393 GB, free: 156.1 MB / 0.9512 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.763e-05/15.7, allocations: 6.531 kB / 3.393 GB, free: 156.1 MB / 0.9512 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.01668/15.72, allocations: 7.852 MB / 3.401 GB, free: 148.1 MB / 0.9512 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.05716/15.78, allocations: 25.54 MB / 3.426 GB, free: 122.5 MB / 0.9512 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 4.055e-05/15.78, allocations: 8 kB / 3.426 GB, free: 122.4 MB / 0.9512 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.004372/15.78, allocations: 0.7572 MB / 3.427 GB, free: 121.7 MB / 0.9512 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.01048/15.79, allocations: 3.039 MB / 3.43 GB, free: 118.6 MB / 0.9512 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.001062/15.79, allocations: 123.9 kB / 3.43 GB, free: 118.5 MB / 0.9512 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.02427/15.82, allocations: 28.86 MB / 3.458 GB, free: 88.43 MB / 0.9512 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 5.841e-06/15.82, allocations: 4.141 kB / 3.458 GB, free: 88.42 MB / 0.9512 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.02845/15.85, allocations: 13.18 MB / 3.471 GB, free: 75.06 MB / 0.9512 GB Notification: Performance of postOpt removeConstants (simulation): time 0.006673/15.85, allocations: 2.394 MB / 3.473 GB, free: 72.64 MB / 0.9512 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.003278/15.86, allocations: 91.98 kB / 3.473 GB, free: 72.55 MB / 0.9512 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.007312/15.86, allocations: 295.7 kB / 3.473 GB, free: 72.26 MB / 0.9512 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0012/15.86, allocations: 295.5 kB / 3.474 GB, free: 71.97 MB / 0.9512 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0007713/15.87, allocations: 139.9 kB / 3.474 GB, free: 71.83 MB / 0.9512 GB Notification: Performance of sorting global known variables: time 0.0143/15.88, allocations: 8.593 MB / 3.482 GB, free: 63.26 MB / 0.9512 GB Notification: Performance of sort global known variables: time 6.21e-07/15.88, allocations: 0 / 3.482 GB, free: 63.26 MB / 0.9512 GB Notification: Performance of remove unused functions: time 0.02273/15.9, allocations: 7.52 MB / 3.49 GB, free: 55.73 MB / 0.9512 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 20 * Number of states: 18 (building2.zone.airvolume.mH2OLiq,building2.zone.airvolume.air.dynBal.U,building2.zone.airvolume.air.dynBal.m,building2.zone.airvolume.air.dynBal.mXi[1],building2.ambientConstructions.construction.layer[1].T[1],building2.groundConstructions.construction.layer[1].T[1],building2.innerConstructions.construction.layer[1].T[1],building2.window[1].heatTransfer.T,building1.zone.airvolume.mH2OLiq,building1.zone.airvolume.air.dynBal.U,building1.zone.airvolume.air.dynBal.m,building1.zone.airvolume.air.dynBal.mXi[1],building1.zone.heatingLoad.I.y,building1.zone.coolingLoad.I.y,building1.ambientConstructions.construction.layer[1].T[1],building1.groundConstructions.construction.layer[1].T[1],building1.innerConstructions.construction.layer[1].T[1],building1.window[1].heatTransfer.T) * Number of discrete variables: 4 ($whenCondition1,ambience2.weatherDataReader.weatherData.conTim.tNext,$whenCondition2,ambience1.weatherDataReader.weatherData.conTim.tNext) * Number of discrete states: 2 (ambience1.weatherDataReader.weatherData.conTim.tNext,ambience2.weatherDataReader.weatherData.conTim.tNext) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (340): * Single equations (assignments): 318 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 2 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 20 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 20 systems {(5,20), (1,1), (1,1), (1,1), (1,1), (1,1), (1,3), (1,3), (1,1), (1,1), (5,20), (1,1), (1,1), (1,1), (1,1), (1,1), (1,3), (1,3), (1,1), (1,1)} Notification: Performance of Backend phase and start with SimCode phase: time 0.0292/15.93, allocations: 14.43 MB / 3.504 GB, free: 41.32 MB / 0.9512 GB Notification: Performance of simCode: created initialization part: time 0.07444/16.01, allocations: 24.86 MB / 3.528 GB, free: 16.21 MB / 0.9512 GB Notification: Performance of simCode: created event and clocks part: time 1.317e-05/16.01, allocations: 3.938 kB / 3.528 GB, free: 16.21 MB / 0.9512 GB Notification: Performance of simCode: created simulation system equations: time 0.01076/16.02, allocations: 4.935 MB / 3.533 GB, free: 11.21 MB / 0.9512 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01348/16.03, allocations: 2.299 MB / 3.535 GB, free: 9.016 MB / 0.9512 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.5473/16.58, allocations: 109.2 MB / 3.642 GB, free: 303 MB / 0.9512 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.01698/16.59, allocations: 9.79 MB / 3.651 GB, free: 293.4 MB / 0.9512 GB Notification: Performance of simCode: alias equations: time 0.01804/16.61, allocations: 5.032 MB / 3.656 GB, free: 288.9 MB / 0.9512 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01092/16.62, allocations: 6.478 MB / 3.663 GB, free: 282.4 MB / 0.9512 GB Notification: Performance of SimCode: time 1.603e-06/16.62, allocations: 0 / 3.663 GB, free: 282.4 MB / 0.9512 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.7111/17.33, allocations: 273.3 MB / 3.929 GB, free: 317.6 MB / 0.9512 GB Notification: Performance of buildModelFMU: Generate platform static: time 36.24/53.57, allocations: 11.36 kB / 3.929 GB, free: 317.6 MB / 0.9512 GB (rm -f BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe ; mkfifo BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe ; head -c 1048576 < BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe >> ../files/BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.sim & /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Buildings_Examples_Building1Zone0D_fmu --startTime=0 --stopTime=3.1536e+07 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Buildings_Examples_Building1Zone0D.fmu > BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe 2>&1)