/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2_fmu --startTime=0 --stopTime=3.1536e+07 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2.fmu LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.SolarThermalSystems.SolarThermalSystem2/temp_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2_fmu/model-gtw163ab/temp/0001_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Egypt_ElGouna.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump1.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump1.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SolarThermalSystem2.pump1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.per.haveWMot_nominal or not (pump1.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump1.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SolarThermalSystem2.pump1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump2.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump2.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SolarThermalSystem2.pump2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.per.haveWMot_nominal or not (pump2.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump2.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SolarThermalSystem2.pump2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." info: maximum step size for 'model.root': 63072.000000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2.weatherData.weatherData.datRea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2.weatherData.weatherData.datRea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2.weatherData.weatherData.info will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2.weatherData.weatherData.tabNam will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 126144.000000 | | | | (((-pump1.dp) <= 4e4)) --> "In SolarThermalSystem2.pump1: Model operates with head -dp = 56499.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem2.pump1.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.SolarThermalSystems.SolarThermalSystem2/temp_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2_fmu/model-gtw163ab/temp/0001_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2 (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/FlowControlled_m_flow.mo:93:3-98:58:writable] | | | | The following assertion has been violated at time 126144.000000 | | | | (((-pump1.dp) <= 4e4)) --> "In SolarThermalSystem2.pump1: Model operates with head -dp = 56499.8 Pa, | | | | exceeding the pressure allowed by the parameter SolarThermalSystem2.pump1.dpMax. | | | | This can happen if the model forces a high mass flow rate through a closed actuator, | | | | or if the performance record is unreasonable. Please verify your model, and | | | | consider using one of the other pump or fan models." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Applications.SolarThermalSystems.SolarThermalSystem2/temp_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2_fmu/model-gtw163ab/temp/0001_BuildingSystems_BuildingSystems_Applications_SolarThermalSystems_SolarThermalSystem2 (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable booleanToReal.u info: Final Statistics for 'model.root': NumSteps = 410 NumRhsEvals = 513 NumLinSolvSetups = 50 NumNonlinSolvIters = 512 NumNonlinSolvConvFails = 0 NumErrTestFails = 7 info: 0 warnings info: 4 errors