/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep_fmu --startTime=0 --stopTime=86400 --timeout=50 --tolerance=1e-06 BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenTop.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenTop can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenTop." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenWes.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenWes can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenWes." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/IBPSA/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not CO2SenEas.warnAboutOnePortConnection)) --> "Sensor CO2TransportStep.CO2SenEas can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'IBPSA.Fluid.MixingVolumes`. | | | | See IBPSA.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in CO2TransportStep.CO2SenEas." info: maximum step size for 'model.root': 172.800000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep.CO2SenEas.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep.CO2SenTop.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep.CO2SenWes.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.BuildSysPro_BuildSysPro_IBPSA_Airflow_Multizone_Examples_CO2TransportStep.sou.substanceName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 518 NumRhsEvals = 533 NumLinSolvSetups = 38 NumNonlinSolvIters = 532 NumNonlinSolvConvFails = 0 NumErrTestFails = 1