/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler_fmu --startTime=0 --stopTime=86400 --timeout=50 --tolerance=1e-06 AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler.fmu info: maximum step size for 'model.root': 60.000000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler.pump.table_minMaxCharacteristics.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler.pump.table_minMaxCharacteristics.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/package.mo:5878:7-5882:3:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bufferStorage.heatingCoil1.pipe[5].vol_a.dynBal.medium.T >= 272.15 and bufferStorage.heatingCoil1.pipe[5].vol_a.dynBal.medium.T <= 403.15)) --> " | | | | Temperature T (= 408.009 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". | | | | " error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.Storage.Examples.StorageBoiler/temp_AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler_fmu/model-hx5trwf6/temp/0001_AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/package.mo:5878:7-5882:3:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bufferStorage.heatingCoil1.pipe[5].vol_a.dynBal.medium.T >= 272.15 and bufferStorage.heatingCoil1.pipe[5].vol_a.dynBal.medium.T <= 403.15)) --> " | | | | Temperature T (= 408.701 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". | | | | " error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.Storage.Examples.StorageBoiler/temp_AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler_fmu/model-hx5trwf6/temp/0001_AixLib_latest_AixLib_Fluid_Storage_Examples_StorageBoiler (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pump.IsNight info: Final Statistics for 'model.root': NumSteps = 582 NumRhsEvals = 1312 NumLinSolvSetups = 171 NumNonlinSolvIters = 1311 NumNonlinSolvConvFails = 8 NumErrTestFails = 47 info: 0 warnings info: 4 errors