/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_latest_AixLib_Fluid_Movers_Validation_FlowControlled_dp_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 AixLib_latest_AixLib_Fluid_Movers_Validation_FlowControlled_dp.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floMacSta.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floMacDyn.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 0.002000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/FlowControlled_dp.mo:89:3-90:95:writable] | | | | The following assertion has been violated at time 0.752000 | | | | ((floMacDyn.dpMachine >= -0.001)) --> "Pressure set point for mover cannot be negative. Obtained dp = -2" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.Movers.Validation.FlowControlled_dp/temp_AixLib_latest_AixLib_Fluid_Movers_Validation_FlowControlled_dp_fmu/model-dyznwpf9/temp/0001_AixLib_latest_AixLib_Fluid_Movers_Validation_FlowControlled_dp (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sou.verifyInputs info: Final Statistics for 'model.root': NumSteps = 133 NumRhsEvals = 139 NumLinSolvSetups = 13 NumNonlinSolvIters = 138 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 2 errors