/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01_fmu --startTime=0 --stopTime=4000 --timeout=50 --tolerance=1e-06 AES_AES_Devel_test_models_Test_liquid_circuit_007_net01.fmu info: maximum step size for 'model.root': 0.400000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Liquid/Pump_centrifugal.mo:28:6-28:67:writable] | | | | The following assertion has been violated at time 3000.800000 | | | | ((pumpC.w >= 0.0)) --> "flow reversal not allowed in centrifugal pump" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Devel_test_models.Test_liquid_circuit_007_net01/temp_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01_fmu/model-e435jary/temp/0001_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01 (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable tube20.fluidStream.hasInertia LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Liquid/Pump_centrifugal.mo:28:6-28:67:writable] | | | | The following assertion has been violated at time 3000.800000 | | | | ((pumpC.w >= 0.0)) --> "flow reversal not allowed in centrifugal pump" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Devel_test_models.Test_liquid_circuit_007_net01/temp_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01_fmu/model-e435jary/temp/0001_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01 (logFmi2Call): internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.AES_AES_Devel_test_models_Test_liquid_circuit_007_net01" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Liquid/Pump_centrifugal.mo:28:6-28:67:writable] | | | | The following assertion has been violated at time 3000.800000 | | | | ((pumpC.w >= 0.0)) --> "flow reversal not allowed in centrifugal pump" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Devel_test_models.Test_liquid_circuit_007_net01/temp_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01_fmu/model-e435jary/temp/0001_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01 (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable tube20.fluidStream.hasInertia LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Liquid/Pump_centrifugal.mo:28:6-28:67:writable] | | | | The following assertion has been violated at time 3000.800000 | | | | ((pumpC.w >= 0.0)) --> "flow reversal not allowed in centrifugal pump" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Devel_test_models.Test_liquid_circuit_007_net01/temp_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01_fmu/model-e435jary/temp/0001_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01 (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.AES_AES_Devel_test_models_Test_liquid_circuit_007_net01" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AES main/ProcessComponents/Thermal/Liquid/Pump_centrifugal.mo:28:6-28:67:writable] | | | | The following assertion has been violated at time 3000.800000 | | | | ((pumpC.w >= 0.0)) --> "flow reversal not allowed in centrifugal pump" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Devel_test_models.Test_liquid_circuit_007_net01/temp_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01_fmu/model-e435jary/temp/0001_AES_AES_Devel_test_models_Test_liquid_circuit_007_net01 (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable tube20.fluidStream.hasInertia info: Final Statistics for 'model.root': NumSteps = 6 NumRhsEvals = 7 NumLinSolvSetups = 6 NumNonlinSolvIters = 6 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 10 errors