Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.00149/0.00149, allocations: 99.75 kB / 18.94 MB, free: 2.832 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001648/0.001648, allocations: 213.5 kB / 22.24 MB, free: 5.105 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.454/1.454, allocations: 230.6 MB / 256 MB, free: 7.805 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo): time 0.8143/0.8143, allocations: 100.3 MB / 412.8 MB, free: 3.422 MB / 318.1 MB " [Timeout remaining time 179] Using package ThermofluidStream with version 1.2.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling,fileNamePrefix="ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: ThermofluidStream requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: ThermofluidStream requested package Complex of version 4.0.0. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002485/0.002485, allocations: 88.02 kB / 0.5633 GB, free: 35.67 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1405/0.143, allocations: 74.46 MB / 0.636 GB, free: 7.402 MB / 478.1 MB Notification: Performance of NFInst.instantiate(ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling): time 0.6313/0.7743, allocations: 239.3 MB / 0.8697 GB, free: 12.55 MB / 0.6231 GB Notification: Performance of NFInst.instExpressions: time 0.009408/0.7837, allocations: 5.076 MB / 0.8746 GB, free: 8.23 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.001523/0.7852, allocations: 45.5 kB / 0.8747 GB, free: 8.211 MB / 0.6231 GB Notification: Performance of NFTyping.typeComponents: time 0.002429/0.7877, allocations: 0.7193 MB / 0.8754 GB, free: 7.68 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.009992/0.7977, allocations: 3.249 MB / 0.8786 GB, free: 4.426 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/AccelerationBoundary.mo:21:3-21:19:writable] Error: acceleration.a[1] is not a valid connector. Notification: Performance of FrontEnd: time 0.00109/0.7987, allocations: 362 kB / 0.8789 GB, free: 4.074 MB / 0.6231 GB " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 4.205095370009076] Failed to read output from testmodel.py, exit status != 0: 0.8054697650077287 0.820894063 -1.0 Calling exit ...