Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001124/0.001124, allocations: 108.2 kB / 17.54 MB, free: 4.742 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001078/0.001078, allocations: 186.7 kB / 20.71 MB, free: 1.586 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.276/1.276, allocations: 207.6 MB / 231.3 MB, free: 3.098 MB / 174.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo): time 0.502/0.502, allocations: 101.8 MB / 385.2 MB, free: 15.43 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020,fileNamePrefix="Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020,fileNamePrefix="Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002627/0.002627, allocations: 71.89 kB / 0.5444 GB, free: 14.38 MB / 414.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1325/0.1351, allocations: 75.38 MB / 0.618 GB, free: 2.91 MB / 478.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020): time 0.2791/0.4142, allocations: 23.02 MB / 0.6405 GB, free: 13.01 MB / 494.1 MB Notification: Performance of NFInst.instExpressions: time 0.01568/0.4299, allocations: 10.33 MB / 0.6505 GB, free: 10.65 MB / 494.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.005596/0.4355, allocations: 113.2 kB / 0.6506 GB, free: 10.62 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Events/NodeFault.mo:24:3-24:107:writable] Warning: Connector nodeFault is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Events/NodeFault.mo:24:3-24:107:writable] Warning: Connector nodeFault is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.004835/0.4403, allocations: 1.812 MB / 0.6524 GB, free: 9.805 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.008254/0.4485, allocations: 2.558 MB / 0.6549 GB, free: 8.363 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:51:3-51:63:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:52:3-52:63:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:54:3-54:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:56:3-56:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:58:3-58:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:60:3-60:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:62:3-62:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:64:3-64:45:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Examples/Wind/IEC/Neplan/WT4BCurrentSource2020.mo:66:3-66:46:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.01168/0.4602, allocations: 5.182 MB / 0.66 GB, free: 5.465 MB / 494.1 MB Notification: Performance of NFFlatten.flatten: time 0.01424/0.4745, allocations: 9.646 MB / 0.6694 GB, free: 256 kB / 494.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.00931/0.4838, allocations: 2.759 MB / 0.6721 GB, free: 15.61 MB / 0.4981 GB Notification: Performance of NFEvalConstants.evaluate: time 0.006453/0.4902, allocations: 3.431 MB / 0.6754 GB, free: 13.2 MB / 0.4981 GB Notification: Performance of NFSimplifyModel.simplify: time 0.00599/0.4962, allocations: 3.796 MB / 0.6791 GB, free: 10.31 MB / 0.4981 GB Notification: Performance of NFPackage.collectConstants: time 0.003212/0.4994, allocations: 1.086 MB / 0.6802 GB, free: 10.31 MB / 0.4981 GB Notification: Performance of NFFlatten.collectFunctions: time 0.003811/0.5032, allocations: 1.35 MB / 0.6815 GB, free: 10.22 MB / 0.4981 GB Notification: Performance of NFScalarize.scalarize: time 0.003985/0.5072, allocations: 2.47 MB / 0.6839 GB, free: 8.258 MB / 0.4981 GB Notification: Performance of NFVerifyModel.verify: time 0.007915/0.5151, allocations: 4.355 MB / 0.6882 GB, free: 4.59 MB / 0.4981 GB Notification: Performance of NFConvertDAE.convert: time 0.02094/0.5361, allocations: 14.92 MB / 0.7028 GB, free: 8.68 MB / 0.5137 GB Notification: Performance of FrontEnd - DAE generated: time 4.689e-06/0.5361, allocations: 0 / 0.7028 GB, free: 8.68 MB / 0.5137 GB Notification: Performance of FrontEnd: time 1.703e-06/0.5361, allocations: 0 / 0.7028 GB, free: 8.68 MB / 0.5137 GB Notification: Performance of Transformations before backend: time 0.0004591/0.5365, allocations: 0 / 0.7028 GB, free: 8.68 MB / 0.5137 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 1169 * Number of variables: 1169 Notification: Performance of Generate backend data structure: time 0.03013/0.5667, allocations: 10.16 MB / 0.7127 GB, free: 15.54 MB / 0.5294 GB Notification: Performance of prepare preOptimizeDAE: time 4.441e-05/0.5667, allocations: 12.03 kB / 0.7127 GB, free: 15.53 MB / 0.5294 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.001874/0.5686, allocations: 0.6212 MB / 0.7133 GB, free: 14.89 MB / 0.5294 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.01/0.5786, allocations: 1.949 MB / 0.7152 GB, free: 12.94 MB / 0.5294 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01171/0.5903, allocations: 5.884 MB / 0.7209 GB, free: 6.984 MB / 0.5294 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0007481/0.5911, allocations: 0.7743 MB / 0.7217 GB, free: 6.121 MB / 0.5294 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001177/0.5922, allocations: 471.9 kB / 0.7222 GB, free: 5.66 MB / 0.5294 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01356/0.6058, allocations: 6.031 MB / 0.728 GB, free: 15.4 MB / 0.545 GB Notification: Performance of preOpt findStateOrder (simulation): time 8.429e-05/0.6059, allocations: 3.938 kB / 0.728 GB, free: 15.39 MB / 0.545 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0007542/0.6066, allocations: 208 kB / 0.7282 GB, free: 15.19 MB / 0.545 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 8.873e-05/0.6067, allocations: 112 kB / 0.7284 GB, free: 15.08 MB / 0.545 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.01163/0.6184, allocations: 4.977 MB / 0.7332 GB, free: 10.09 MB / 0.545 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.04016/0.6585, allocations: 25.81 MB / 0.7584 GB, free: 15.14 MB / 0.5762 GB Notification: Performance of preOpt comSubExp (simulation): time 0.01018/0.6687, allocations: 4.786 MB / 0.7631 GB, free: 10.31 MB / 0.5762 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.005132/0.6738, allocations: 2.624 MB / 0.7657 GB, free: 7.691 MB / 0.5762 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0002711/0.6741, allocations: 79.02 kB / 0.7657 GB, free: 7.617 MB / 0.5762 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.006375/0.6805, allocations: 3.326 MB / 0.769 GB, free: 4.238 MB / 0.5762 GB Notification: Performance of pre-optimization done (n=448): time 7.193e-06/0.6805, allocations: 0 / 0.769 GB, free: 4.238 MB / 0.5762 GB Notification: Performance of matching and sorting (n=448): time 0.03666/0.7171, allocations: 11.94 MB / 0.7806 GB, free: 8.262 MB / 0.5919 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0005249/0.7177, allocations: 0.931 MB / 0.7815 GB, free: 7.121 MB / 0.5919 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01475/0.7324, allocations: 7.516 MB / 0.7889 GB, free: 15.63 MB / 0.6075 GB Notification: Performance of collectPreVariables (initialization): time 0.0005078/0.7329, allocations: 133.7 kB / 0.789 GB, free: 15.5 MB / 0.6075 GB Notification: Performance of collectInitialEqns (initialization): time 0.003942/0.7369, allocations: 3.284 MB / 0.7922 GB, free: 12.2 MB / 0.6075 GB Notification: Performance of collectInitialBindings (initialization): time 0.001761/0.7386, allocations: 1.472 MB / 0.7937 GB, free: 10.71 MB / 0.6075 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.001606/0.7402, allocations: 0.7607 MB / 0.7944 GB, free: 9.938 MB / 0.6075 GB Notification: Performance of setup shared object (initialization): time 0.0001253/0.7404, allocations: 305.1 kB / 0.7947 GB, free: 9.637 MB / 0.6075 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.004826/0.7452, allocations: 2.287 MB / 0.7969 GB, free: 7.328 MB / 0.6075 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.00573/0.7509, allocations: 3.197 MB / 0.8 GB, free: 3.816 MB / 0.6075 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.02742/0.7783, allocations: 10.56 MB / 0.8104 GB, free: 9.035 MB / 0.6231 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 1.794e-05/0.7784, allocations: 4 kB / 0.8104 GB, free: 9.031 MB / 0.6231 GB Notification: Performance of matching and sorting (n=557) (initialization): time 0.01649/0.7948, allocations: 7.197 MB / 0.8174 GB, free: 1.801 MB / 0.6231 GB Notification: Performance of prepare postOptimizeDAE: time 5.084e-05/0.7949, allocations: 37.7 kB / 0.8174 GB, free: 1.758 MB / 0.6231 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 3.336e-05/0.7949, allocations: 12 kB / 0.8174 GB, free: 1.746 MB / 0.6231 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003934/0.7989, allocations: 1.841 MB / 0.8192 GB, free: 15.89 MB / 0.6387 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002923/0.8018, allocations: 0.7136 MB / 0.8199 GB, free: 15.18 MB / 0.6387 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03036/0.8321, allocations: 18.73 MB / 0.8382 GB, free: 11.75 MB / 0.6544 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.004942/0.8371, allocations: 0.548 MB / 0.8387 GB, free: 11.2 MB / 0.6544 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0006824/0.8378, allocations: 155.9 kB / 0.8389 GB, free: 11.05 MB / 0.6544 GB Warning: Assuming fixed start value for the following 34 variables: line1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line1.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) wT4BCurrentSource.wT4Injector.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = wT4BCurrentSource.wT4Injector.State0 fixed = true ) \"Injector connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) wT4BCurrentSource.wT4Injector.running.value:DISCRETE(flow=false start = wT4BCurrentSource.wT4Injector.Running0 fixed = true ) type: Boolean wT4BCurrentSource.pll.fixedBooleanDelay1.y:DISCRETE(flow=false start = wT4BCurrentSource.pll.fixedBooleanDelay1.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4BCurrentSource.pll.fixedBooleanDelay.y:DISCRETE(flow=false start = wT4BCurrentSource.pll.fixedBooleanDelay.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4BCurrentSource.control4B.pControl4B.firstOrder.y:VARIABLE(flow=false start = -wT4BCurrentSource.mechanical.P0Pu * 100.0 / wT4BCurrentSource.mechanical.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.control4B.qControl.derivative.x:VARIABLE(start = wT4BCurrentSource.control4B.qControl.derivative.x_start fixed = true ) \"State of block\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder.y:VARIABLE(flow=false start = -wT4BCurrentSource.protectionMeasurements.P0Pu * 100.0 / wT4BCurrentSource.protectionMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder1.y:VARIABLE(flow=false start = -wT4BCurrentSource.protectionMeasurements.Q0Pu * 100.0 / wT4BCurrentSource.protectionMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder2.y:VARIABLE(flow=false start = 100.0 * (wT4BCurrentSource.protectionMeasurements.i0Pu.re ^ 2.0 + wT4BCurrentSource.protectionMeasurements.i0Pu.im ^ 2.0) ^ 0.5 / wT4BCurrentSource.protectionMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder3.y:VARIABLE(flow=false start = wT4BCurrentSource.gridProtection.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder4.y:VARIABLE(flow=false start = wT4BCurrentSource.protectionMeasurements.firstOrder4.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.derivative.x:VARIABLE(start = wT4BCurrentSource.protectionMeasurements.derivative.x_start fixed = true ) \"State of block\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder.y:VARIABLE(flow=false start = -wT4BCurrentSource.control4B.qControl.P0Pu * 100.0 / wT4BCurrentSource.control4B.qControl.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder1.y:VARIABLE(flow=false start = -wT4BCurrentSource.control4B.qControl.Q0Pu * 100.0 / wT4BCurrentSource.control4B.qControl.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder2.y:VARIABLE(flow=false start = 100.0 * (wT4BCurrentSource.controlMeasurements.i0Pu.re ^ 2.0 + wT4BCurrentSource.controlMeasurements.i0Pu.im ^ 2.0) ^ 0.5 / wT4BCurrentSource.controlMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder3.y:VARIABLE(flow=false start = wT4BCurrentSource.control4B.pControl4B.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder4.y:VARIABLE(flow=false start = wT4BCurrentSource.controlMeasurements.firstOrder4.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.derivative.x:VARIABLE(start = wT4BCurrentSource.controlMeasurements.derivative.x_start fixed = true ) \"State of block\" type: Real nodeFault1.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean transformer1.running.value:DISCRETE(flow=false start = transformer1.Running0 fixed = true ) type: Boolean transformer.running.value:DISCRETE(flow=false start = transformer.Running0 fixed = true ) type: Boolean line4.running.value:DISCRETE(flow=false start = line4.Running0 fixed = true ) type: Boolean line.running.value:DISCRETE(flow=false start = line.Running0 fixed = true ) type: Boolean line2.running.value:DISCRETE(flow=false start = line2.Running0 fixed = true ) type: Boolean line3.running.value:DISCRETE(flow=false start = line3.Running0 fixed = true ) type: Boolean line1.running.value:DISCRETE(flow=false start = line1.Running0 fixed = true ) type: Boolean nodeFault.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.007884/0.8457, allocations: 3.564 MB / 0.8424 GB, free: 7.484 MB / 0.6544 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.005125/0.8508, allocations: 2.846 MB / 0.8452 GB, free: 4.332 MB / 0.6544 GB Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 0.02547/0.8762, allocations: 9.744 MB / 0.8547 GB, free: 10.36 MB / 0.67 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 1.833e-05/0.8763, allocations: 4 kB / 0.8547 GB, free: 10.36 MB / 0.67 GB Notification: Performance of matching and sorting (n=557) (initialization_lambda0): time 0.01484/0.8911, allocations: 6.572 MB / 0.8611 GB, free: 3.75 MB / 0.67 GB Notification: Performance of prepare postOptimizeDAE: time 5.264e-05/0.8912, allocations: 42.69 kB / 0.8611 GB, free: 3.703 MB / 0.67 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 2.348e-05/0.8912, allocations: 12 kB / 0.8611 GB, free: 3.691 MB / 0.67 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.003919/0.8951, allocations: 1.86 MB / 0.863 GB, free: 1.812 MB / 0.67 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002463/0.8976, allocations: 0.6161 MB / 0.8636 GB, free: 1.195 MB / 0.67 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03016/0.9277, allocations: 18.71 MB / 0.8818 GB, free: 13.78 MB / 0.7012 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.004556/0.9323, allocations: 450.4 kB / 0.8823 GB, free: 13.34 MB / 0.7012 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0005095/0.9328, allocations: 152 kB / 0.8824 GB, free: 13.19 MB / 0.7012 GB Warning: Assuming fixed start value for the following 34 variables: line1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line1.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) line4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = line4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) transformer1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = transformer1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) wT4BCurrentSource.wT4Injector.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = wT4BCurrentSource.wT4Injector.State0 fixed = true ) \"Injector connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) wT4BCurrentSource.wT4Injector.running.value:DISCRETE(flow=false start = wT4BCurrentSource.wT4Injector.Running0 fixed = true ) type: Boolean wT4BCurrentSource.pll.fixedBooleanDelay1.y:DISCRETE(flow=false start = wT4BCurrentSource.pll.fixedBooleanDelay1.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4BCurrentSource.pll.fixedBooleanDelay.y:DISCRETE(flow=false start = wT4BCurrentSource.pll.fixedBooleanDelay.Y0 fixed = true ) \"Connector of Boolean output signal\" type: Boolean wT4BCurrentSource.control4B.pControl4B.firstOrder.y:VARIABLE(flow=false start = -wT4BCurrentSource.mechanical.P0Pu * 100.0 / wT4BCurrentSource.mechanical.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.control4B.qControl.derivative.x:VARIABLE(start = wT4BCurrentSource.control4B.qControl.derivative.x_start fixed = true ) \"State of block\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder.y:VARIABLE(flow=false start = -wT4BCurrentSource.protectionMeasurements.P0Pu * 100.0 / wT4BCurrentSource.protectionMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder1.y:VARIABLE(flow=false start = -wT4BCurrentSource.protectionMeasurements.Q0Pu * 100.0 / wT4BCurrentSource.protectionMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder2.y:VARIABLE(flow=false start = 100.0 * (wT4BCurrentSource.protectionMeasurements.i0Pu.re ^ 2.0 + wT4BCurrentSource.protectionMeasurements.i0Pu.im ^ 2.0) ^ 0.5 / wT4BCurrentSource.protectionMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder3.y:VARIABLE(flow=false start = wT4BCurrentSource.gridProtection.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.firstOrder4.y:VARIABLE(flow=false start = wT4BCurrentSource.protectionMeasurements.firstOrder4.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.protectionMeasurements.derivative.x:VARIABLE(start = wT4BCurrentSource.protectionMeasurements.derivative.x_start fixed = true ) \"State of block\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder.y:VARIABLE(flow=false start = -wT4BCurrentSource.control4B.qControl.P0Pu * 100.0 / wT4BCurrentSource.control4B.qControl.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder1.y:VARIABLE(flow=false start = -wT4BCurrentSource.control4B.qControl.Q0Pu * 100.0 / wT4BCurrentSource.control4B.qControl.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder2.y:VARIABLE(flow=false start = 100.0 * (wT4BCurrentSource.controlMeasurements.i0Pu.re ^ 2.0 + wT4BCurrentSource.controlMeasurements.i0Pu.im ^ 2.0) ^ 0.5 / wT4BCurrentSource.controlMeasurements.SNom fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder3.y:VARIABLE(flow=false start = wT4BCurrentSource.control4B.pControl4B.U0Pu fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.firstOrder4.y:VARIABLE(flow=false start = wT4BCurrentSource.controlMeasurements.firstOrder4.y_start fixed = true ) \"Connector of Real output signal\" type: Real wT4BCurrentSource.controlMeasurements.derivative.x:VARIABLE(start = wT4BCurrentSource.controlMeasurements.derivative.x_start fixed = true ) \"State of block\" type: Real nodeFault1.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean transformer1.running.value:DISCRETE(flow=false start = transformer1.Running0 fixed = true ) type: Boolean transformer.running.value:DISCRETE(flow=false start = transformer.Running0 fixed = true ) type: Boolean line4.running.value:DISCRETE(flow=false start = line4.Running0 fixed = true ) type: Boolean line.running.value:DISCRETE(flow=false start = line.Running0 fixed = true ) type: Boolean line2.running.value:DISCRETE(flow=false start = line2.Running0 fixed = true ) type: Boolean line3.running.value:DISCRETE(flow=false start = line3.Running0 fixed = true ) type: Boolean line1.running.value:DISCRETE(flow=false start = line1.Running0 fixed = true ) type: Boolean nodeFault.nodeFault.value:DISCRETE(flow=false start = false fixed = true ) type: Boolean Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 62 * Number of states: 0 () * Number of discrete variables: 157 ($PRE.line1.state,line1.state,$PRE.line3.state,line3.state,$PRE.line2.state,line2.state,$PRE.line.state,line.state,$PRE.line4.state,line4.state,$PRE.transformer.state,transformer.state,$PRE.transformer1.state,transformer1.state,$PRE.wT4BCurrentSource.wT4Injector.state,wT4BCurrentSource.wT4Injector.state,$whenCondition36,$whenCondition37,$whenCondition13,$whenCondition14,transformer1.switchOffSignal2.value,transformer1.switchOffSignal1.value,transformer.switchOffSignal2.value,transformer.switchOffSignal1.value,line4.switchOffSignal2.value,line4.switchOffSignal1.value,line3.switchOffSignal2.value,line3.switchOffSignal1.value,line2.switchOffSignal2.value,line2.switchOffSignal1.value,line1.switchOffSignal2.value,line1.switchOffSignal1.value,line.switchOffSignal2.value,line.switchOffSignal1.value,wT4BCurrentSource.wT4Injector.switchOffSignal3.value,wT4BCurrentSource.wT4Injector.switchOffSignal2.value,wT4BCurrentSource.wT4Injector.switchOffSignal1.value,$PRE.wT4BCurrentSource.wT4Injector.running.value,$PRE.wT4BCurrentSource.pll.fixedBooleanDelay1.y,$PRE.wT4BCurrentSource.pll.fixedBooleanDelay.y,$PRE.nodeFault1.nodeFault.value,$PRE.transformer1.running.value,$PRE.transformer.running.value,$PRE.line4.running.value,$PRE.line.running.value,$PRE.line2.running.value,$PRE.line3.running.value,$PRE.line1.running.value,$PRE.nodeFault.nodeFault.value,$PRE.omegaRefPu.count,$PRE.omegaRefPu.T_start,$PRE.wT4BCurrentSource.gridProtection.pre1.u,$PRE.wT4BCurrentSource.gridProtection.timer3.entryTime,$PRE.wT4BCurrentSource.gridProtection.timer2.entryTime,$PRE.wT4BCurrentSource.gridProtection.timer1.entryTime,$PRE.wT4BCurrentSource.gridProtection.timer.entryTime,$PRE.wT4BCurrentSource.control4B.qControl.delayFlag.timer.entryTime,wT4BCurrentSource.control4B.currentLimiter.product1.u[2],omegaRefPu.count,omegaRefPu.T_start,nodeFault.nodeFault.value,line1.running.value,line3.running.value,line2.running.value,line.running.value,line4.running.value,transformer.running.value,transformer1.running.value,nodeFault1.nodeFault.value,wT4BCurrentSource.gridProtection.pre1.u,wT4BCurrentSource.gridProtection.or1.u[5],wT4BCurrentSource.gridProtection.or1.u[4],wT4BCurrentSource.gridProtection.or1.u[3],wT4BCurrentSource.gridProtection.or1.u[2],wT4BCurrentSource.gridProtection.or1.u[1],wT4BCurrentSource.gridProtection.timer3.entryTime,wT4BCurrentSource.gridProtection.timer2.entryTime,wT4BCurrentSource.gridProtection.timer1.entryTime,wT4BCurrentSource.gridProtection.lessEqual3.y,wT4BCurrentSource.gridProtection.lessEqual2.y,wT4BCurrentSource.gridProtection.lessEqual1.y,wT4BCurrentSource.gridProtection.lessEqual.y,wT4BCurrentSource.gridProtection.timer.entryTime,wT4BCurrentSource.control4B.currentLimiter.greater.y,wT4BCurrentSource.control4B.currentLimiter.product1.y,wT4BCurrentSource.control4B.qControl.greaterThreshold.y,wT4BCurrentSource.control4B.qControl.booleanToInteger.y,wT4BCurrentSource.control4B.qControl.fFrt,wT4BCurrentSource.control4B.qControl.greaterEqualThreshold.y,wT4BCurrentSource.control4B.qControl.delayFlag.booleanToInteger.y,wT4BCurrentSource.control4B.qControl.delayFlag.switch1.y,wT4BCurrentSource.control4B.qControl.delayFlag.less1.y,wT4BCurrentSource.control4B.qControl.delayFlag.timer.entryTime,wT4BCurrentSource.control4B.qControl.delayFlag.fO,wT4BCurrentSource.control4B.qControl.delayFlag.fI,wT4BCurrentSource.control4B.pControl4B.less.y,wT4BCurrentSource.control4B.pControl4B.and1.y,wT4BCurrentSource.control4B.qLimiter.integerToBoolean.y,wT4BCurrentSource.pll.fixedBooleanDelay.y,wT4BCurrentSource.pll.fixedBooleanDelay1.y,wT4BCurrentSource.pll.lessThreshold1.y,wT4BCurrentSource.pll.lessThreshold.y,wT4BCurrentSource.wT4Injector.running.value,$whenCondition2,$whenCondition1,$whenCondition3,$whenCondition5,$whenCondition4,$whenCondition7,$whenCondition6,$whenCondition8,$whenCondition9,$whenCondition10,$whenCondition11,$whenCondition12,$whenCondition16,$whenCondition15,$whenCondition17,$whenCondition19,$whenCondition18,$whenCondition20,$whenCondition22,$whenCondition21,$whenCondition23,$whenCondition25,$whenCondition24,$whenCondition26,$whenCondition28,$whenCondition27,$whenCondition29,$whenCondition31,$whenCondition30,$whenCondition32,$whenCondition34,$whenCondition33,$whenCondition35,$whenCondition38,$whenCondition40,$whenCondition39,$whenCondition42,$whenCondition41,wT4BCurrentSource.controlMeasurements.rampLimiter.integrator.local_reset,wT4BCurrentSource.protectionMeasurements.rampLimiter.integrator.local_reset,wT4BCurrentSource.mechanical.pI.integrator.local_reset,wT4BCurrentSource.mechanical.integrator1.local_reset,wT4BCurrentSource.mechanical.integrator.local_reset,wT4BCurrentSource.control4B.qControl.absLimRateLimFeedthroughFreeze.rampLimiter.integrator.local_reset,wT4BCurrentSource.control4B.qControl.absLimRateLimFirstOrderFreeze.integrator.local_reset,wT4BCurrentSource.control4B.qControl.antiWindupIntegrator1.integrator.local_reset,wT4BCurrentSource.control4B.qControl.antiWindupIntegrator.integrator.local_reset,wT4BCurrentSource.control4B.pControl4B.rampLimiter.integrator.local_reset,wT4BCurrentSource.control4B.pControl4B.absLimRateLimFirstOrderAntiWindup.integrator.local_reset,wT4BCurrentSource.control4B.qLimiter.absLimRateLimFeedthroughFreeze1.rampLimiter.integrator.local_reset,wT4BCurrentSource.control4B.qLimiter.absLimRateLimFeedthroughFreeze.rampLimiter.integrator.local_reset,wT4BCurrentSource.pll.absLimRateLimFirstOrderFreeze.integrator.local_reset,wT4BCurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup1.integrator.local_reset,wT4BCurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup.integrator.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (480): * Single equations (assignments): 474 * Array equations: 0 * Algorithm blocks: 1 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 5 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 4 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(32,41)} Notification: Performance of prepare postOptimizeDAE: time 0.001888/0.9347, allocations: 0.7142 MB / 0.8831 GB, free: 12.47 MB / 0.7012 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.002193/0.9369, allocations: 0.7413 MB / 0.8838 GB, free: 11.73 MB / 0.7012 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01612/0.953, allocations: 6.701 MB / 0.8904 GB, free: 4.988 MB / 0.7012 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 3.485e-05/0.953, allocations: 44 kB / 0.8904 GB, free: 4.945 MB / 0.7012 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.215e-05/0.953, allocations: 7.922 kB / 0.8904 GB, free: 4.938 MB / 0.7012 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 5.195e-05/0.9531, allocations: 19.92 kB / 0.8904 GB, free: 4.918 MB / 0.7012 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.03568/0.9888, allocations: 16.93 MB / 0.907 GB, free: 3.863 MB / 0.7169 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.058e-05/0.9888, allocations: 4 kB / 0.907 GB, free: 3.859 MB / 0.7169 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.002866/0.9916, allocations: 0.6123 MB / 0.9076 GB, free: 3.246 MB / 0.7169 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.003673/0.9953, allocations: 1.705 MB / 0.9093 GB, free: 1.543 MB / 0.7169 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0003852/0.9957, allocations: 104 kB / 0.9094 GB, free: 1.441 MB / 0.7169 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.2753/1.271, allocations: 12.85 MB / 0.9219 GB, free: 233.7 MB / 0.7169 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 3.046e-06/1.271, allocations: 4.375 kB / 0.9219 GB, free: 233.7 MB / 0.7169 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.0231/1.294, allocations: 10.62 MB / 0.9323 GB, free: 229.7 MB / 0.7169 GB Notification: Performance of postOpt removeConstants (simulation): time 0.002343/1.296, allocations: 1.001 MB / 0.9333 GB, free: 229.3 MB / 0.7169 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0009624/1.297, allocations: 108.4 kB / 0.9334 GB, free: 229.3 MB / 0.7169 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.003065/1.3, allocations: 329.8 kB / 0.9337 GB, free: 229.2 MB / 0.7169 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0009333/1.301, allocations: 351.3 kB / 0.934 GB, free: 229.1 MB / 0.7169 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0002804/1.302, allocations: 145.1 kB / 0.9341 GB, free: 229.1 MB / 0.7169 GB Notification: Performance of sorting global known variables: time 0.008355/1.31, allocations: 5.14 MB / 0.9392 GB, free: 227.3 MB / 0.7169 GB Notification: Performance of sort global known variables: time 2.51e-07/1.31, allocations: 0 / 0.9392 GB, free: 227.3 MB / 0.7169 GB Notification: Performance of remove unused functions: time 0.009407/1.319, allocations: 2.661 MB / 0.9418 GB, free: 226.8 MB / 0.7169 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 1 * Number of states: 30 (wT4BCurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup.integrator.y,wT4BCurrentSource.wT4Injector.genSystem.absLimRateLimFirstOrderAntiWindup1.integrator.y,wT4BCurrentSource.pll.absLimRateLimFirstOrderFreeze.integrator.y,wT4BCurrentSource.control4B.qLimiter.absLimRateLimFeedthroughFreeze.rampLimiter.integrator.y,wT4BCurrentSource.control4B.qLimiter.absLimRateLimFeedthroughFreeze1.rampLimiter.integrator.y,wT4BCurrentSource.control4B.pControl4B.absLimRateLimFirstOrderAntiWindup.integrator.y,wT4BCurrentSource.control4B.pControl4B.firstOrder.y,wT4BCurrentSource.control4B.pControl4B.rampLimiter.integrator.y,wT4BCurrentSource.control4B.qControl.antiWindupIntegrator.integrator.y,wT4BCurrentSource.control4B.qControl.antiWindupIntegrator1.integrator.y,wT4BCurrentSource.control4B.qControl.absLimRateLimFirstOrderFreeze.integrator.y,wT4BCurrentSource.control4B.qControl.absLimRateLimFeedthroughFreeze.rampLimiter.integrator.y,wT4BCurrentSource.control4B.qControl.derivative.x,wT4BCurrentSource.mechanical.integrator.y,wT4BCurrentSource.mechanical.integrator1.y,wT4BCurrentSource.mechanical.pI.integrator.y,wT4BCurrentSource.protectionMeasurements.firstOrder.y,wT4BCurrentSource.protectionMeasurements.firstOrder1.y,wT4BCurrentSource.protectionMeasurements.firstOrder2.y,wT4BCurrentSource.protectionMeasurements.firstOrder3.y,wT4BCurrentSource.protectionMeasurements.firstOrder4.y,wT4BCurrentSource.protectionMeasurements.rampLimiter.integrator.y,wT4BCurrentSource.protectionMeasurements.derivative.x,wT4BCurrentSource.controlMeasurements.firstOrder.y,wT4BCurrentSource.controlMeasurements.firstOrder1.y,wT4BCurrentSource.controlMeasurements.firstOrder2.y,wT4BCurrentSource.controlMeasurements.firstOrder3.y,wT4BCurrentSource.controlMeasurements.firstOrder4.y,wT4BCurrentSource.controlMeasurements.rampLimiter.integrator.y,wT4BCurrentSource.controlMeasurements.derivative.x) * Number of discrete variables: 95 (wT4BCurrentSource.gridProtection.or1.u[1],wT4BCurrentSource.gridProtection.or1.u[2],wT4BCurrentSource.gridProtection.or1.u[3],wT4BCurrentSource.gridProtection.or1.u[4],wT4BCurrentSource.gridProtection.lessEqual2.y,wT4BCurrentSource.gridProtection.lessEqual3.y,wT4BCurrentSource.gridProtection.lessEqual1.y,wT4BCurrentSource.gridProtection.lessEqual.y,wT4BCurrentSource.control4B.qControl.delayFlag.fI,$whenCondition41,$whenCondition42,$whenCondition39,$whenCondition40,$whenCondition38,$whenCondition36,$whenCondition37,$whenCondition35,$whenCondition33,$whenCondition34,$whenCondition32,$whenCondition30,$whenCondition31,$whenCondition29,$whenCondition27,$whenCondition28,$whenCondition26,$whenCondition24,$whenCondition25,$whenCondition23,$whenCondition21,$whenCondition22,$whenCondition20,$whenCondition18,$whenCondition19,$whenCondition17,$whenCondition15,$whenCondition16,$whenCondition13,$whenCondition14,$whenCondition12,$whenCondition11,$whenCondition10,$whenCondition9,$whenCondition8,$whenCondition6,$whenCondition7,$whenCondition4,$whenCondition5,$whenCondition3,$whenCondition1,$whenCondition2,wT4BCurrentSource.wT4Injector.running.value,wT4BCurrentSource.wT4Injector.state,wT4BCurrentSource.pll.lessThreshold.y,wT4BCurrentSource.pll.lessThreshold1.y,wT4BCurrentSource.pll.fixedBooleanDelay1.y,wT4BCurrentSource.pll.fixedBooleanDelay.y,wT4BCurrentSource.control4B.qLimiter.integerToBoolean.y,wT4BCurrentSource.control4B.pControl4B.and1.y,wT4BCurrentSource.control4B.pControl4B.less.y,wT4BCurrentSource.control4B.qControl.delayFlag.fO,wT4BCurrentSource.control4B.qControl.delayFlag.timer.entryTime,wT4BCurrentSource.control4B.qControl.delayFlag.less1.y,wT4BCurrentSource.control4B.qControl.delayFlag.switch1.y,wT4BCurrentSource.control4B.qControl.delayFlag.booleanToInteger.y,wT4BCurrentSource.control4B.qControl.greaterEqualThreshold.y,wT4BCurrentSource.control4B.qControl.fFrt,wT4BCurrentSource.control4B.qControl.booleanToInteger.y,wT4BCurrentSource.control4B.qControl.greaterThreshold.y,wT4BCurrentSource.control4B.currentLimiter.product1.y,wT4BCurrentSource.control4B.currentLimiter.greater.y,wT4BCurrentSource.gridProtection.timer.entryTime,wT4BCurrentSource.gridProtection.timer1.entryTime,wT4BCurrentSource.gridProtection.timer2.entryTime,wT4BCurrentSource.gridProtection.timer3.entryTime,wT4BCurrentSource.gridProtection.or1.u[5],wT4BCurrentSource.gridProtection.pre1.u,nodeFault1.nodeFault.value,transformer1.running.value,transformer1.state,transformer.running.value,transformer.state,line4.running.value,line4.state,line.running.value,line.state,line2.running.value,line2.state,line3.running.value,line3.state,line1.running.value,line1.state,nodeFault.nodeFault.value,omegaRefPu.T_start,omegaRefPu.count) * Number of discrete states: 10 (omegaRefPu.count,line1.running.value,line3.running.value,line2.running.value,line.running.value,line4.running.value,transformer.running.value,transformer1.running.value,wT4BCurrentSource.wT4Injector.running.value,wT4BCurrentSource.gridProtection.pre1.u) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (378): * Single equations (assignments): 350 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 27 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(32,43)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02138/1.341, allocations: 11.69 MB / 0.9532 GB, free: 221.8 MB / 0.7169 GB Notification: Performance of simCode: created initialization part: time 0.01797/1.359, allocations: 10.43 MB / 0.9634 GB, free: 215 MB / 0.7169 GB Notification: Performance of simCode: created event and clocks part: time 1.068e-05/1.359, allocations: 0.875 kB / 0.9634 GB, free: 215 MB / 0.7169 GB Notification: Performance of simCode: created simulation system equations: time 0.00723/1.366, allocations: 3.449 MB / 0.9667 GB, free: 211.9 MB / 0.7169 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.007379/1.373, allocations: 1.176 MB / 0.9679 GB, free: 211 MB / 0.7169 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.1108/1.484, allocations: 64.44 MB / 1.031 GB, free: 146.9 MB / 0.7169 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.003637/1.488, allocations: 3.522 MB / 1.034 GB, free: 143.4 MB / 0.7169 GB Notification: Performance of simCode: alias equations: time 0.004332/1.492, allocations: 1.031 MB / 1.035 GB, free: 142.3 MB / 0.7169 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.004095/1.496, allocations: 3.202 MB / 1.038 GB, free: 139.1 MB / 0.7169 GB Notification: Performance of SimCode: time 7.52e-07/1.496, allocations: 4 kB / 1.038 GB, free: 139.1 MB / 0.7169 GB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.5063/2.003, allocations: 178.7 MB / 1.213 GB, free: 231.4 MB / 0.7325 GB Error: Error building simulator. Build log: cmd: cd '508.fmutmp/sources/' && mkdir build_cmake_static && cd build_cmake_static && cmake -DCMAKE_BUILD_TYPE=Release -DCMAKE_C_COMPILER='clang' .. && cmake --build . --parallel -j1 --target install && cd .. && rm -rf build_cmake_static -- The C compiler identification is Clang 14.0.0 -- Detecting C compiler ABI info -- Detecting C compiler ABI info - done -- Check for working C compiler: /usr/bin/clang - skipped -- Detecting C compile features -- Detecting C compile features - done -- FMI2 include directory: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi -- Looking for pthread.h -- Looking for pthread.h - found -- Performing Test CMAKE_HAVE_LIBC_PTHREAD -- Performing Test CMAKE_HAVE_LIBC_PTHREAD - Success -- Found Threads: TRUE -- Building for FMI platform linux64 -- Install directory: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020/508.fmutmp/sources/../binaries/linux64 -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaStandardTables.a -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaIO.a -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaMatIO.a -- Linking /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libzlib.a -- CVODE: Not linked -- Not using FMI2_FUNCTION_PREFIX -- Installing dynamic dependencies from list: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaStandardTables.a;/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaIO.a;/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libModelicaMatIO.a;/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libzlib.a -- Configuring done -- Generating done -- Build files have been written to: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020/508.fmutmp/sources/build_cmake_static [ 0%] Building C object CMakeFiles/508.dir/external_solvers/dgemm.c.o [ 1%] Building C object CMakeFiles/508.dir/external_solvers/dger.c.o [ 2%] Building C object CMakeFiles/508.dir/external_solvers/dgesv.c.o [ 3%] Building C object CMakeFiles/508.dir/external_solvers/dgetf2.c.o [ 4%] Building C object CMakeFiles/508.dir/external_solvers/dgetrf.c.o [ 5%] Building C object CMakeFiles/508.dir/external_solvers/dgetrs.c.o [ 6%] Building C object CMakeFiles/508.dir/external_solvers/dlamch.c.o [ 7%] Building C object CMakeFiles/508.dir/external_solvers/dlaswp.c.o [ 8%] Building C object CMakeFiles/508.dir/external_solvers/dogleg_.c.o [ 9%] Building C object CMakeFiles/508.dir/external_solvers/dpmpar_.c.o [ 10%] Building C object CMakeFiles/508.dir/external_solvers/dscal.c.o [ 11%] Building C object CMakeFiles/508.dir/external_solvers/dswap.c.o [ 12%] Building C object CMakeFiles/508.dir/external_solvers/dtrsm.c.o [ 12%] Building C object CMakeFiles/508.dir/external_solvers/enorm_.c.o [ 13%] Building C object CMakeFiles/508.dir/external_solvers/hybrj_.c.o [ 14%] Building C object CMakeFiles/508.dir/external_solvers/i_nint.c.o [ 15%] Building C object CMakeFiles/508.dir/external_solvers/idamax.c.o [ 16%] Building C object CMakeFiles/508.dir/external_solvers/ieeeck.c.o [ 17%] Building C object CMakeFiles/508.dir/external_solvers/ilaenv.c.o [ 18%] Building C object CMakeFiles/508.dir/external_solvers/iparmq.c.o [ 19%] Building C object CMakeFiles/508.dir/external_solvers/lsame.c.o [ 20%] Building C object CMakeFiles/508.dir/external_solvers/pow_di.c.o [ 21%] Building C object CMakeFiles/508.dir/external_solvers/qform_.c.o [ 22%] Building C object CMakeFiles/508.dir/external_solvers/qrfac_.c.o [ 23%] Building C object CMakeFiles/508.dir/external_solvers/r1mpyq_.c.o [ 24%] Building C object CMakeFiles/508.dir/external_solvers/r1updt_.c.o [ 25%] Building C object CMakeFiles/508.dir/external_solvers/s_cmp.c.o [ 25%] Building C object CMakeFiles/508.dir/external_solvers/s_copy.c.o [ 26%] Building C object CMakeFiles/508.dir/external_solvers/xerbla.c.o [ 27%] Building C object CMakeFiles/508.dir/gc/memory_pool.c.o [ 28%] Building C object CMakeFiles/508.dir/gc/omc_gc.c.o [ 29%] Building C object CMakeFiles/508.dir/math-support/pivot.c.o [ 30%] Building C object CMakeFiles/508.dir/meta/meta_modelica_catch.c.o [ 31%] Building C object CMakeFiles/508.dir/simulation/jacobian_util.c.o [ 32%] Building C object CMakeFiles/508.dir/simulation/omc_simulation_util.c.o [ 33%] Building C object CMakeFiles/508.dir/simulation/options.c.o [ 34%] Building C object CMakeFiles/508.dir/simulation/simulation_info_json.c.o [ 35%] Building C object CMakeFiles/508.dir/simulation/simulation_omc_assert.c.o [ 36%] Building C object CMakeFiles/508.dir/simulation/solver/delay.c.o [ 37%] Building C object CMakeFiles/508.dir/simulation/solver/fmi_events.c.o [ 37%] Building C object CMakeFiles/508.dir/simulation/solver/initialization/initialization.c.o [ 38%] Building C object CMakeFiles/508.dir/simulation/solver/linearSolverLapack.c.o [ 39%] Building C object CMakeFiles/508.dir/simulation/solver/linearSolverTotalPivot.c.o [ 40%] Building C object CMakeFiles/508.dir/simulation/solver/linearSystem.c.o [ 41%] Building C object CMakeFiles/508.dir/simulation/solver/model_help.c.o [ 42%] Building C object CMakeFiles/508.dir/simulation/solver/nonlinearSolverHomotopy.c.o [ 43%] Building C object CMakeFiles/508.dir/simulation/solver/nonlinearSolverHybrd.c.o [ 44%] Building C object CMakeFiles/508.dir/simulation/solver/nonlinearSystem.c.o [ 45%] Building C object CMakeFiles/508.dir/simulation/solver/nonlinearValuesList.c.o [ 46%] Building C object CMakeFiles/508.dir/simulation/solver/omc_math.c.o [ 47%] Building C object CMakeFiles/508.dir/simulation/solver/spatialDistribution.c.o [ 48%] Building C object CMakeFiles/508.dir/simulation/solver/stateset.c.o [ 49%] Building C object CMakeFiles/508.dir/simulation/solver/synchronous.c.o [ 50%] Building C object CMakeFiles/508.dir/util/ModelicaUtilities.c.o [ 50%] Building C object CMakeFiles/508.dir/util/base_array.c.o [ 51%] Building C object CMakeFiles/508.dir/util/boolean_array.c.o [ 52%] Building C object CMakeFiles/508.dir/util/context.c.o [ 53%] Building C object CMakeFiles/508.dir/util/division.c.o [ 54%] Building C object CMakeFiles/508.dir/util/doubleEndedList.c.o [ 55%] Building C object CMakeFiles/508.dir/util/generic_array.c.o [ 56%] Building C object CMakeFiles/508.dir/util/index_spec.c.o [ 57%] Building C object CMakeFiles/508.dir/util/integer_array.c.o [ 58%] Building C object CMakeFiles/508.dir/util/list.c.o [ 59%] Building C object CMakeFiles/508.dir/util/modelica_string.c.o [ 60%] Building C object CMakeFiles/508.dir/util/modelica_string_lit.c.o [ 61%] Building C object CMakeFiles/508.dir/util/omc_error.c.o [ 62%] Building C object CMakeFiles/508.dir/util/omc_file.c.o [ 62%] Building C object CMakeFiles/508.dir/util/omc_init.c.o [ 63%] Building C object CMakeFiles/508.dir/util/omc_mmap.c.o [ 64%] Building C object CMakeFiles/508.dir/util/omc_msvc.c.o [ 65%] Building C object CMakeFiles/508.dir/util/omc_numbers.c.o [ 66%] Building C object CMakeFiles/508.dir/util/parallel_helper.c.o [ 67%] Building C object CMakeFiles/508.dir/util/rational.c.o [ 68%] Building C object CMakeFiles/508.dir/util/real_array.c.o [ 69%] Building C object CMakeFiles/508.dir/util/ringbuffer.c.o [ 70%] Building C object CMakeFiles/508.dir/util/simulation_options.c.o [ 71%] Building C object CMakeFiles/508.dir/util/string_array.c.o [ 72%] Building C object CMakeFiles/508.dir/util/utility.c.o [ 73%] Building C object CMakeFiles/508.dir/util/varinfo.c.o [ 74%] Building C object CMakeFiles/508.dir/Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020.c.o /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Dynawo_dev_Dynawo.Examples.Wind.IEC.Neplan.WT4BCurrentSource2020/508.fmutmp/sources/Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020.c:8:10: fatal error: 'Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020_16dae.h' file not found #include \"Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020_16dae.h\" ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 1 error generated. gmake[2]: *** [CMakeFiles/508.dir/build.make:1182: CMakeFiles/508.dir/Dynawo_dev_Dynawo_Examples_Wind_IEC_Neplan_WT4BCurrentSource2020.c.o] Error 1 gmake[1]: *** [CMakeFiles/Makefile2:84: CMakeFiles/508.dir/all] Error 2 gmake: *** [Makefile:136: all] Error 2 " [Timeout remaining time 649] [Calling sys.exit(0), Time elapsed: 13.629074896001839]