Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_1.6.1_Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001374/0.001374, allocations: 108.2 kB / 17.54 MB, free: 4.766 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001373/0.001373, allocations: 182.7 kB / 20.71 MB, free: 1.609 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.247/1.247, allocations: 207.6 MB / 231.3 MB, free: 3.375 MB / 174.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/package.mo): time 0.4968/0.4968, allocations: 101.9 MB / 385.3 MB, free: 15.37 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.7.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent,fileNamePrefix="Dynawo_1_6_1_Dynawo_Examples_IEEE14_TestCases_IEEE14NoEvent",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent,fileNamePrefix="Dynawo_1_6_1_Dynawo_Examples_IEEE14_TestCases_IEEE14NoEvent",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002557/0.002557, allocations: 67.83 kB / 0.5416 GB, free: 1.184 MB / 398.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1272/0.1298, allocations: 75.38 MB / 0.6152 GB, free: 5.719 MB / 478.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.IEEE14.TestCases.IEEE14NoEvent): time 0.01817/0.1479, allocations: 17.98 MB / 0.6327 GB, free: 3.656 MB / 494.1 MB Notification: Performance of NFInst.instExpressions: time 0.2437/0.3916, allocations: 7.281 MB / 0.6398 GB, free: 9.727 MB / 494.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.001751/0.3934, allocations: 75.75 kB / 0.6399 GB, free: 9.727 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001925/0.3953, allocations: 0.9751 MB / 0.6409 GB, free: 9.727 MB / 494.1 MB Notification: Performance of NFTyping.typeBindings: time 0.002299/0.3976, allocations: 1.142 MB / 0.642 GB, free: 9.723 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:105:3-105:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:106:3-106:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:108:3-108:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:109:3-109:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:111:3-111:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:112:3-112:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:114:3-114:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:115:3-115:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:117:3-117:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:118:3-118:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:121:3-121:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:123:3-123:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:125:3-125:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:127:3-127:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:129:3-129:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:131:3-131:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:133:3-133:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:135:3-135:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:137:3-137:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:139:3-139:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:141:3-141:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:144:3-144:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:146:3-146:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:148:3-148:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:150:3-150:70:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:152:3-152:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:154:3-154:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:156:3-156:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:158:3-158:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:160:3-160:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:162:3-162:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:164:3-164:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:166:3-166:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:168:3-168:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:170:3-170:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:172:3-172:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:174:3-174:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:176:3-176:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:179:3-179:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:181:3-181:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:183:3-183:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Examples/IEEE14/TestCases/IEEE14NoEvent.mo:186:3-186:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.005704/0.4033, allocations: 3.014 MB / 0.6449 GB, free: 9.617 MB / 494.1 MB Notification: Performance of NFFlatten.flatten: time 0.005307/0.4086, allocations: 5.42 MB / 0.6502 GB, free: 8.184 MB / 494.1 MB Notification: Performance of NFFlatten.resolveConnections: time 0.001428/0.4101, allocations: 0.8072 MB / 0.651 GB, free: 7.734 MB / 494.1 MB Notification: Performance of NFEvalConstants.evaluate: time 0.003155/0.4132, allocations: 2.127 MB / 0.6531 GB, free: 6.711 MB / 494.1 MB Notification: Performance of NFSimplifyModel.simplify: time 0.004015/0.4172, allocations: 2.589 MB / 0.6556 GB, free: 5.512 MB / 494.1 MB Notification: Performance of NFPackage.collectConstants: time 0.001749/0.419, allocations: 472.7 kB / 0.656 GB, free: 5.508 MB / 494.1 MB Notification: Performance of NFFlatten.collectFunctions: time 0.002616/0.4216, allocations: 0.6701 MB / 0.6567 GB, free: 5.457 MB / 494.1 MB Notification: Performance of NFScalarize.scalarize: time 0.002133/0.4237, allocations: 1.188 MB / 0.6579 GB, free: 4.766 MB / 494.1 MB Notification: Performance of NFVerifyModel.verify: time 0.003705/0.4274, allocations: 2.279 MB / 0.6601 GB, free: 3.277 MB / 494.1 MB Notification: Performance of NFConvertDAE.convert: time 0.005457/0.4329, allocations: 5.554 MB / 0.6655 GB, free: 80 kB / 494.1 MB Notification: Performance of FrontEnd - DAE generated: time 4.027e-06/0.4329, allocations: 1.281 kB / 0.6655 GB, free: 80 kB / 494.1 MB Notification: Performance of FrontEnd: time 1.753e-06/0.4329, allocations: 0 / 0.6655 GB, free: 80 kB / 494.1 MB Notification: Performance of Transformations before backend: time 7.046e-05/0.433, allocations: 0 / 0.6655 GB, free: 80 kB / 494.1 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 784 * Number of variables: 784 Notification: Performance of Generate backend data structure: time 0.02744/0.4604, allocations: 9.136 MB / 0.6744 GB, free: 10.45 MB / 0.4981 GB Notification: Performance of prepare preOptimizeDAE: time 4.167e-05/0.4605, allocations: 9.719 kB / 0.6744 GB, free: 10.45 MB / 0.4981 GB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.0007191/0.4612, allocations: 0.5064 MB / 0.6749 GB, free: 10.06 MB / 0.4981 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.01879/0.48, allocations: 3.104 MB / 0.678 GB, free: 8.805 MB / 0.4981 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.006735/0.4867, allocations: 2.924 MB / 0.6808 GB, free: 6.777 MB / 0.4981 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001545/0.4882, allocations: 2.255 MB / 0.683 GB, free: 4.348 MB / 0.4981 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0006872/0.4889, allocations: 367.1 kB / 0.6834 GB, free: 4.223 MB / 0.4981 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.007723/0.4966, allocations: 4.484 MB / 0.6878 GB, free: 1.551 MB / 0.4981 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.159e-05/0.4967, allocations: 0 / 0.6878 GB, free: 1.551 MB / 0.4981 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0004614/0.4972, allocations: 183.6 kB / 0.6879 GB, free: 1.418 MB / 0.4981 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 4.638e-05/0.4972, allocations: 71 kB / 0.688 GB, free: 1.418 MB / 0.4981 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.006817/0.504, allocations: 3.99 MB / 0.6919 GB, free: 14.29 MB / 0.5137 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.02997/0.534, allocations: 18.6 MB / 0.7101 GB, free: 11.32 MB / 0.5294 GB Notification: Performance of preOpt comSubExp (simulation): time 0.006554/0.5405, allocations: 3.721 MB / 0.7137 GB, free: 7.598 MB / 0.5294 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.004511/0.545, allocations: 2.569 MB / 0.7162 GB, free: 5.031 MB / 0.5294 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0003787/0.5454, allocations: 138.6 kB / 0.7163 GB, free: 4.883 MB / 0.5294 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.007777/0.5532, allocations: 4.651 MB / 0.7209 GB, free: 200 kB / 0.5294 GB Notification: Performance of pre-optimization done (n=624): time 7.855e-06/0.5532, allocations: 0 / 0.7209 GB, free: 200 kB / 0.5294 GB Notification: Performance of matching and sorting (n=624): time 0.02622/0.5794, allocations: 11.76 MB / 0.7324 GB, free: 4.355 MB / 0.545 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001691/0.5796, allocations: 185.2 kB / 0.7325 GB, free: 4.168 MB / 0.545 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.003905/0.5835, allocations: 2.32 MB / 0.7348 GB, free: 1.844 MB / 0.545 GB Notification: Performance of collectPreVariables (initialization): time 0.0006721/0.5842, allocations: 229.6 kB / 0.735 GB, free: 1.613 MB / 0.545 GB Notification: Performance of collectInitialEqns (initialization): time 0.001296/0.5855, allocations: 1.356 MB / 0.7363 GB, free: 272 kB / 0.545 GB Notification: Performance of collectInitialBindings (initialization): time 0.0022/0.5877, allocations: 1.859 MB / 0.7382 GB, free: 14.47 MB / 0.5606 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.002072/0.5897, allocations: 0.9826 MB / 0.7391 GB, free: 13.48 MB / 0.5606 GB Notification: Performance of setup shared object (initialization): time 0.0001196/0.5899, allocations: 301.1 kB / 0.7394 GB, free: 13.18 MB / 0.5606 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.004932/0.5948, allocations: 2.504 MB / 0.7419 GB, free: 10.67 MB / 0.5606 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.006053/0.6008, allocations: 3.896 MB / 0.7457 GB, free: 6.227 MB / 0.5606 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.0297/0.6306, allocations: 13.41 MB / 0.7587 GB, free: 8.156 MB / 0.5762 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 5.566e-05/0.6306, allocations: 12 kB / 0.7588 GB, free: 8.145 MB / 0.5762 GB Notification: Performance of matching and sorting (n=858) (initialization): time 0.0369/0.6675, allocations: 11.6 MB / 0.7701 GB, free: 12.46 MB / 0.5919 GB Notification: Performance of prepare postOptimizeDAE: time 6.463e-05/0.6676, allocations: 20.97 kB / 0.7701 GB, free: 12.45 MB / 0.5919 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 6.861e-05/0.6676, allocations: 40 kB / 0.7701 GB, free: 12.41 MB / 0.5919 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01284/0.6805, allocations: 7.817 MB / 0.7778 GB, free: 4.586 MB / 0.5919 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.007261/0.6877, allocations: 1.423 MB / 0.7792 GB, free: 3.16 MB / 0.5919 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01201/0.6997, allocations: 5.371 MB / 0.7844 GB, free: 13.75 MB / 0.6075 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.005025/0.7048, allocations: 0.5016 MB / 0.7849 GB, free: 13.25 MB / 0.6075 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.000844/0.7056, allocations: 244 kB / 0.7851 GB, free: 13.01 MB / 0.6075 GB Warning: Assuming fixed start value for the following 106 variables: Gen1.limUQUp:DISCRETE(start = Gen1.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen1.limUQDown:DISCRETE(start = Gen1.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen2.limUQUp:DISCRETE(start = Gen2.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen2.limUQDown:DISCRETE(start = Gen2.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen3.limUQUp:DISCRETE(start = Gen3.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen3.limUQDown:DISCRETE(start = Gen3.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen6.limUQUp:DISCRETE(start = Gen6.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen6.limUQDown:DISCRETE(start = Gen6.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen8.limUQUp:DISCRETE(start = Gen8.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen8.limUQDown:DISCRETE(start = Gen8.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Load2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load2.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load3.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load4.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load5.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load6.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load6.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load9.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load10.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load10.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load11.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load12.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load13.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load14.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB10B11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB10B11.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB12B13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB12B13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB13B14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB13B14.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB1B2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB1B2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB1B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB1B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB3B4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB3B4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB4B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB4B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B11.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B12.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB7B8.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB7B8.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB7B9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB7B9.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB9B10.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB9B10.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB9B14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB9B14.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo2.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo3.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Bank9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Bank9.State0 fixed = true ) \"Shunt connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen8.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen8.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen6.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen6.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen3.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen2.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen1.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen1.running.value:DISCRETE(flow=false start = Gen1.Running0 fixed = true ) type: Boolean Gen2.running.value:DISCRETE(flow=false start = Gen2.Running0 fixed = true ) type: Boolean Gen3.running.value:DISCRETE(flow=false start = Gen3.Running0 fixed = true ) type: Boolean Gen6.running.value:DISCRETE(flow=false start = Gen6.Running0 fixed = true ) type: Boolean Gen8.running.value:DISCRETE(flow=false start = Gen8.Running0 fixed = true ) type: Boolean ModelSignalN.thetaRef:VARIABLE(start = 0.0 unit = \"rad\" fixed = true ) \"Voltage angle reference\" type: Real Load2.running.value:DISCRETE(flow=false start = Load2.Running0 fixed = true ) type: Boolean Load2.UFilteredRawPu:VARIABLE(start = (Load2.u0Pu.re ^ 2.0 + Load2.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load3.running.value:DISCRETE(flow=false start = Load3.Running0 fixed = true ) type: Boolean Load3.UFilteredRawPu:VARIABLE(start = (Load3.u0Pu.re ^ 2.0 + Load3.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load4.running.value:DISCRETE(flow=false start = Load4.Running0 fixed = true ) type: Boolean Load4.UFilteredRawPu:VARIABLE(start = (Load4.u0Pu.re ^ 2.0 + Load4.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load5.running.value:DISCRETE(flow=false start = Load5.Running0 fixed = true ) type: Boolean Load5.UFilteredRawPu:VARIABLE(start = (Load5.u0Pu.re ^ 2.0 + Load5.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load6.running.value:DISCRETE(flow=false start = Load6.Running0 fixed = true ) type: Boolean Load6.UFilteredRawPu:VARIABLE(start = (Load6.u0Pu.re ^ 2.0 + Load6.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load9.running.value:DISCRETE(flow=false start = Load9.Running0 fixed = true ) type: Boolean Load9.UFilteredRawPu:VARIABLE(start = (Load9.u0Pu.re ^ 2.0 + Load9.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load10.running.value:DISCRETE(flow=false start = Load10.Running0 fixed = true ) type: Boolean Load10.UFilteredRawPu:VARIABLE(start = (Load10.u0Pu.re ^ 2.0 + Load10.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load11.running.value:DISCRETE(flow=false start = Load11.Running0 fixed = true ) type: Boolean Load11.UFilteredRawPu:VARIABLE(start = (Load11.u0Pu.re ^ 2.0 + Load11.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load12.running.value:DISCRETE(flow=false start = Load12.Running0 fixed = true ) type: Boolean Load12.UFilteredRawPu:VARIABLE(start = (Load12.u0Pu.re ^ 2.0 + Load12.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load13.running.value:DISCRETE(flow=false start = Load13.Running0 fixed = true ) type: Boolean Load13.UFilteredRawPu:VARIABLE(start = (Load13.u0Pu.re ^ 2.0 + Load13.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load14.running.value:DISCRETE(flow=false start = Load14.Running0 fixed = true ) type: Boolean Load14.UFilteredRawPu:VARIABLE(start = (Load14.u0Pu.re ^ 2.0 + Load14.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real LineB10B11.running.value:DISCRETE(flow=false start = LineB10B11.Running0 fixed = true ) type: Boolean LineB12B13.running.value:DISCRETE(flow=false start = LineB12B13.Running0 fixed = true ) type: Boolean LineB13B14.running.value:DISCRETE(flow=false start = LineB13B14.Running0 fixed = true ) type: Boolean LineB1B2.running.value:DISCRETE(flow=false start = LineB1B2.Running0 fixed = true ) type: Boolean LineB1B5.running.value:DISCRETE(flow=false start = LineB1B5.Running0 fixed = true ) type: Boolean LineB2B3.running.value:DISCRETE(flow=false start = LineB2B3.Running0 fixed = true ) type: Boolean LineB2B4.running.value:DISCRETE(flow=false start = LineB2B4.Running0 fixed = true ) type: Boolean LineB2B5.running.value:DISCRETE(flow=false start = LineB2B5.Running0 fixed = true ) type: Boolean LineB3B4.running.value:DISCRETE(flow=false start = LineB3B4.Running0 fixed = true ) type: Boolean LineB4B5.running.value:DISCRETE(flow=false start = LineB4B5.Running0 fixed = true ) type: Boolean LineB6B11.running.value:DISCRETE(flow=false start = LineB6B11.Running0 fixed = true ) type: Boolean LineB6B12.running.value:DISCRETE(flow=false start = LineB6B12.Running0 fixed = true ) type: Boolean LineB6B13.running.value:DISCRETE(flow=false start = LineB6B13.Running0 fixed = true ) type: Boolean LineB7B8.running.value:DISCRETE(flow=false start = LineB7B8.Running0 fixed = true ) type: Boolean LineB7B9.running.value:DISCRETE(flow=false start = LineB7B9.Running0 fixed = true ) type: Boolean LineB9B10.running.value:DISCRETE(flow=false start = LineB9B10.Running0 fixed = true ) type: Boolean LineB9B14.running.value:DISCRETE(flow=false start = LineB9B14.Running0 fixed = true ) type: Boolean Tfo1.running.value:DISCRETE(flow=false start = Tfo1.Running0 fixed = true ) type: Boolean Tfo2.running.value:DISCRETE(flow=false start = Tfo2.Running0 fixed = true ) type: Boolean Tfo3.running.value:DISCRETE(flow=false start = Tfo3.Running0 fixed = true ) type: Boolean Bank9.running.value:DISCRETE(flow=false start = Bank9.Running0 fixed = true ) type: Boolean Gen8.qStatus:DISCRETE(min = Gen8.QStatus.Standard max = Gen8.QStatus.GenerationMax start = Gen8.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen8.pStatus:DISCRETE(min = Gen8.PStatus.Standard max = Gen8.PStatus.LimitPMax start = Gen8.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen6.qStatus:DISCRETE(min = Gen6.QStatus.Standard max = Gen6.QStatus.GenerationMax start = Gen6.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen6.pStatus:DISCRETE(min = Gen6.PStatus.Standard max = Gen6.PStatus.LimitPMax start = Gen6.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen3.qStatus:DISCRETE(min = Gen3.QStatus.Standard max = Gen3.QStatus.GenerationMax start = Gen3.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen3.pStatus:DISCRETE(min = Gen3.PStatus.Standard max = Gen3.PStatus.LimitPMax start = Gen3.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen2.qStatus:DISCRETE(min = Gen2.QStatus.Standard max = Gen2.QStatus.GenerationMax start = Gen2.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen2.pStatus:DISCRETE(min = Gen2.PStatus.Standard max = Gen2.PStatus.LimitPMax start = Gen2.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen1.qStatus:DISCRETE(min = Gen1.QStatus.Standard max = Gen1.QStatus.GenerationMax start = Gen1.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen1.pStatus:DISCRETE(min = Gen1.PStatus.Standard max = Gen1.PStatus.LimitPMax start = Gen1.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 177 * Number of states: 0 () * Number of discrete variables: 434 ($PRE.Gen1.limUQUp,Gen1.limUQUp,$PRE.Gen1.limUQDown,Gen1.limUQDown,$PRE.Gen2.limUQUp,Gen2.limUQUp,$PRE.Gen2.limUQDown,Gen2.limUQDown,$PRE.Gen3.limUQUp,Gen3.limUQUp,$PRE.Gen3.limUQDown,Gen3.limUQDown,$PRE.Gen6.limUQUp,Gen6.limUQUp,$PRE.Gen6.limUQDown,Gen6.limUQDown,$PRE.Gen8.limUQUp,Gen8.limUQUp,$PRE.Gen8.limUQDown,Gen8.limUQDown,$PRE.Load2.state,Load2.state,$PRE.Load3.state,Load3.state,$PRE.Load4.state,Load4.state,$PRE.Load5.state,Load5.state,$PRE.Load6.state,Load6.state,$PRE.Load9.state,Load9.state,$PRE.Load10.state,Load10.state,$PRE.Load11.state,Load11.state,$PRE.Load12.state,Load12.state,$PRE.Load13.state,Load13.state,$PRE.Load14.state,Load14.state,$PRE.LineB10B11.state,LineB10B11.state,$PRE.LineB12B13.state,LineB12B13.state,$PRE.LineB13B14.state,LineB13B14.state,$PRE.LineB1B2.state,LineB1B2.state,$PRE.LineB1B5.state,LineB1B5.state,$PRE.LineB2B3.state,LineB2B3.state,$PRE.LineB2B4.state,LineB2B4.state,$PRE.LineB2B5.state,LineB2B5.state,$PRE.LineB3B4.state,LineB3B4.state,$PRE.LineB4B5.state,LineB4B5.state,$PRE.LineB6B11.state,LineB6B11.state,$PRE.LineB6B12.state,LineB6B12.state,$PRE.LineB6B13.state,LineB6B13.state,$PRE.LineB7B8.state,LineB7B8.state,$PRE.LineB7B9.state,LineB7B9.state,$PRE.LineB9B10.state,LineB9B10.state,$PRE.LineB9B14.state,LineB9B14.state,$PRE.Tfo1.state,Tfo1.state,$PRE.Tfo2.state,Tfo2.state,$PRE.Tfo3.state,Tfo3.state,$PRE.Bank9.state,Bank9.state,$PRE.Gen8.state,Gen8.converter.u,Gen8.state,$PRE.Gen6.state,Gen6.converter.u,Gen6.state,$PRE.Gen3.state,Gen3.converter.u,Gen3.state,$PRE.Gen2.state,Gen2.converter.u,Gen2.state,$PRE.Gen1.state,Gen1.converter.u,Gen1.state,$PRE.Gen1.running.value,$PRE.Gen2.running.value,$PRE.Gen3.running.value,$PRE.Gen6.running.value,$PRE.Gen8.running.value,$PRE.Load2.running.value,$PRE.Load3.running.value,$PRE.Load4.running.value,$PRE.Load5.running.value,$PRE.Load6.running.value,$PRE.Load9.running.value,$PRE.Load10.running.value,$PRE.Load11.running.value,$PRE.Load12.running.value,$PRE.Load13.running.value,$PRE.Load14.running.value,$PRE.LineB10B11.running.value,$PRE.LineB12B13.running.value,$PRE.LineB13B14.running.value,$PRE.LineB1B2.running.value,$PRE.LineB1B5.running.value,$PRE.LineB2B3.running.value,$PRE.LineB2B4.running.value,$PRE.LineB2B5.running.value,$PRE.LineB3B4.running.value,$PRE.LineB4B5.running.value,$PRE.LineB6B11.running.value,$PRE.LineB6B12.running.value,$PRE.LineB6B13.running.value,$PRE.LineB7B8.running.value,$PRE.LineB7B9.running.value,$PRE.LineB9B10.running.value,$PRE.LineB9B14.running.value,$PRE.Tfo1.running.value,$PRE.Tfo2.running.value,$PRE.Tfo3.running.value,$PRE.Bank9.running.value,$PRE.Gen8.qStatus,$PRE.Gen8.pStatus,$PRE.Gen6.qStatus,$PRE.Gen6.pStatus,$PRE.Gen3.qStatus,$PRE.Gen3.pStatus,$PRE.Gen2.qStatus,$PRE.Gen2.pStatus,$PRE.Gen1.qStatus,$PRE.Gen1.pStatus,Bank9.running.value,Tfo3.running.value,Tfo2.running.value,Tfo1.running.value,LineB9B14.running.value,LineB9B10.running.value,LineB7B9.running.value,LineB7B8.running.value,LineB6B13.running.value,LineB6B12.running.value,LineB6B11.running.value,LineB4B5.running.value,LineB3B4.running.value,LineB2B5.running.value,LineB2B4.running.value,LineB2B3.running.value,LineB1B5.running.value,LineB1B5.switchOffSignal2.value,LineB1B2.running.value,LineB13B14.running.value,LineB12B13.running.value,LineB10B11.running.value,Load14.running.value,Load13.running.value,Load12.running.value,Load11.running.value,Load10.running.value,Load9.running.value,Load6.running.value,Load5.running.value,Load4.running.value,Load3.running.value,Load2.running.value,Gen8.qStatus,Gen8.pStatus,Gen8.running.value,Gen6.qStatus,Gen6.pStatus,Gen6.running.value,Gen3.qStatus,Gen3.pStatus,Gen3.running.value,Gen2.qStatus,Gen2.pStatus,Gen2.running.value,Gen1.qStatus,Gen1.pStatus,Gen1.running.value,$whenCondition1,$whenCondition3,$whenCondition2,$whenCondition4,$whenCondition6,$whenCondition5,$whenCondition7,$whenCondition9,$whenCondition8,$whenCondition10,$whenCondition12,$whenCondition11,$whenCondition13,$whenCondition15,$whenCondition14,$whenCondition16,$whenCondition18,$whenCondition17,$whenCondition19,$whenCondition21,$whenCondition20,$whenCondition22,$whenCondition24,$whenCondition23,$whenCondition25,$whenCondition27,$whenCondition26,$whenCondition28,$whenCondition30,$whenCondition29,$whenCondition31,$whenCondition33,$whenCondition32,$whenCondition34,$whenCondition36,$whenCondition35,$whenCondition37,$whenCondition39,$whenCondition38,$whenCondition40,$whenCondition42,$whenCondition41,$whenCondition43,$whenCondition45,$whenCondition44,$whenCondition46,$whenCondition48,$whenCondition47,$whenCondition50,$whenCondition49,$whenCondition52,$whenCondition51,$whenCondition53,$whenCondition55,$whenCondition54,$whenCondition56,$whenCondition58,$whenCondition57,$whenCondition59,$whenCondition61,$whenCondition60,$whenCondition62,$whenCondition64,$whenCondition63,$whenCondition65,$whenCondition67,$whenCondition66,$whenCondition68,$whenCondition70,$whenCondition69,$whenCondition71,$whenCondition73,$whenCondition72,$whenCondition74,$whenCondition76,$whenCondition75,$whenCondition77,$whenCondition79,$whenCondition78,$whenCondition80,$whenCondition82,$whenCondition81,$whenCondition83,$whenCondition85,$whenCondition84,$whenCondition86,$whenCondition88,$whenCondition87,$whenCondition89,$whenCondition91,$whenCondition90,$whenCondition92,$whenCondition94,$whenCondition93,$whenCondition95,$whenCondition97,$whenCondition96,$whenCondition98,$whenCondition100,$whenCondition99,$whenCondition104,$whenCondition103,$whenCondition102,$whenCondition101,$whenCondition107,$whenCondition106,$whenCondition105,$whenCondition108,$whenCondition110,$whenCondition109,$whenCondition114,$whenCondition113,$whenCondition112,$whenCondition111,$whenCondition117,$whenCondition116,$whenCondition115,$whenCondition118,$whenCondition120,$whenCondition119,$whenCondition124,$whenCondition123,$whenCondition122,$whenCondition121,$whenCondition127,$whenCondition126,$whenCondition125,$whenCondition128,$whenCondition130,$whenCondition129,$whenCondition134,$whenCondition133,$whenCondition132,$whenCondition131,$whenCondition137,$whenCondition136,$whenCondition135,$whenCondition138,$whenCondition140,$whenCondition139,$whenCondition144,$whenCondition143,$whenCondition142,$whenCondition141,$whenCondition147,$whenCondition146,$whenCondition145,$whenCondition150,$whenCondition149,$whenCondition148,$whenCondition153,$whenCondition152,$whenCondition151,$whenCondition156,$whenCondition155,$whenCondition154,$whenCondition159,$whenCondition158,$whenCondition157,$whenCondition162,$whenCondition161,$whenCondition160,Bank9.switchOffSignal2.value,Bank9.switchOffSignal1.value,Tfo3.switchOffSignal2.value,Tfo3.switchOffSignal1.value,Tfo2.switchOffSignal2.value,Tfo2.switchOffSignal1.value,Tfo1.switchOffSignal2.value,Tfo1.switchOffSignal1.value,LineB9B14.switchOffSignal2.value,LineB9B14.switchOffSignal1.value,LineB9B10.switchOffSignal2.value,LineB9B10.switchOffSignal1.value,LineB7B9.switchOffSignal2.value,LineB7B9.switchOffSignal1.value,LineB7B8.switchOffSignal2.value,LineB7B8.switchOffSignal1.value,LineB6B13.switchOffSignal2.value,LineB6B13.switchOffSignal1.value,LineB6B12.switchOffSignal2.value,LineB6B12.switchOffSignal1.value,LineB6B11.switchOffSignal2.value,LineB6B11.switchOffSignal1.value,LineB4B5.switchOffSignal2.value,LineB4B5.switchOffSignal1.value,LineB3B4.switchOffSignal2.value,LineB3B4.switchOffSignal1.value,LineB2B5.switchOffSignal2.value,LineB2B5.switchOffSignal1.value,LineB2B4.switchOffSignal2.value,LineB2B4.switchOffSignal1.value,LineB2B3.switchOffSignal2.value,LineB2B3.switchOffSignal1.value,LineB1B2.switchOffSignal2.value,LineB1B2.switchOffSignal1.value,LineB1B5.switchOffSignal1.value,LineB13B14.switchOffSignal2.value,LineB13B14.switchOffSignal1.value,LineB12B13.switchOffSignal2.value,LineB12B13.switchOffSignal1.value,LineB10B11.switchOffSignal2.value,LineB10B11.switchOffSignal1.value,Load14.switchOffSignal2.value,Load14.switchOffSignal1.value,Load13.switchOffSignal2.value,Load13.switchOffSignal1.value,Load12.switchOffSignal2.value,Load12.switchOffSignal1.value,Load11.switchOffSignal2.value,Load11.switchOffSignal1.value,Load10.switchOffSignal2.value,Load10.switchOffSignal1.value,Load9.switchOffSignal2.value,Load9.switchOffSignal1.value,Load6.switchOffSignal2.value,Load6.switchOffSignal1.value,Load5.switchOffSignal2.value,Load5.switchOffSignal1.value,Load4.switchOffSignal2.value,Load4.switchOffSignal1.value,Load3.switchOffSignal2.value,Load3.switchOffSignal1.value,Load2.switchOffSignal2.value,Load2.switchOffSignal1.value,Gen8.switchOffSignal3.value,Gen8.switchOffSignal2.value,Gen8.switchOffSignal1.value,Gen6.switchOffSignal3.value,Gen6.switchOffSignal2.value,Gen6.switchOffSignal1.value,Gen3.switchOffSignal3.value,Gen3.switchOffSignal2.value,Gen3.switchOffSignal1.value,Gen2.switchOffSignal3.value,Gen2.switchOffSignal2.value,Gen2.switchOffSignal1.value,Gen1.switchOffSignal3.value,Gen1.switchOffSignal2.value,Gen1.switchOffSignal1.value) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (673): * Single equations (assignments): 672 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(115,71)} Notification: Performance of prepare postOptimizeDAE: time 0.003624/0.7092, allocations: 1.546 MB / 0.7866 GB, free: 11.48 MB / 0.6075 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001667/0.7109, allocations: 0.5166 MB / 0.7871 GB, free: 10.96 MB / 0.6075 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01714/0.7281, allocations: 8.502 MB / 0.7955 GB, free: 2.367 MB / 0.6075 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 5.832e-05/0.7281, allocations: 59.98 kB / 0.7955 GB, free: 2.309 MB / 0.6075 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.74e-05/0.7281, allocations: 8 kB / 0.7955 GB, free: 2.301 MB / 0.6075 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 5.75e-05/0.7282, allocations: 27.89 kB / 0.7955 GB, free: 2.273 MB / 0.6075 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02696/0.7551, allocations: 15.45 MB / 0.8106 GB, free: 2.812 MB / 0.6231 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.335e-05/0.7552, allocations: 0 / 0.8106 GB, free: 2.812 MB / 0.6231 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.006149/0.7613, allocations: 1.174 MB / 0.8118 GB, free: 1.637 MB / 0.6231 GB Warning: The tearing heuristic was not able to avoid discrete iteration variables because otherwise the system could not have been torn. This may lead to problems during simulation. Notification: Performance of postOpt tearingSystem (simulation): time 0.01139/0.7727, allocations: 6.734 MB / 0.8184 GB, free: 10.9 MB / 0.6387 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0008016/0.7735, allocations: 155.9 kB / 0.8185 GB, free: 10.75 MB / 0.6387 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.01272/0.7862, allocations: 15.51 MB / 0.8336 GB, free: 9.727 MB / 0.6544 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.673e-06/0.7862, allocations: 0 / 0.8336 GB, free: 9.727 MB / 0.6544 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.02575/0.812, allocations: 12.41 MB / 0.8458 GB, free: 13.19 MB / 0.67 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001434/0.8134, allocations: 0.5637 MB / 0.8463 GB, free: 12.61 MB / 0.67 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001266/0.8147, allocations: 179.9 kB / 0.8465 GB, free: 12.43 MB / 0.67 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.004011/0.8187, allocations: 295.7 kB / 0.8468 GB, free: 12.14 MB / 0.67 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001515/0.8202, allocations: 0.5235 MB / 0.8473 GB, free: 11.61 MB / 0.67 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.000779/0.821, allocations: 283.9 kB / 0.8476 GB, free: 11.34 MB / 0.67 GB Notification: Performance of sorting global known variables: time 0.002522/0.8235, allocations: 1.436 MB / 0.849 GB, free: 9.902 MB / 0.67 GB Notification: Performance of sort global known variables: time 1e-07/0.8235, allocations: 0 / 0.849 GB, free: 9.902 MB / 0.67 GB Notification: Performance of remove unused functions: time 0.004679/0.8282, allocations: 1.448 MB / 0.8504 GB, free: 8.453 MB / 0.67 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 1 * Number of states: 12 (ModelSignalN.thetaRef,Load2.UFilteredRawPu,Load3.UFilteredRawPu,Load4.UFilteredRawPu,Load5.UFilteredRawPu,Load6.UFilteredRawPu,Load9.UFilteredRawPu,Load10.UFilteredRawPu,Load11.UFilteredRawPu,Load12.UFilteredRawPu,Load13.UFilteredRawPu,Load14.UFilteredRawPu) * Number of discrete variables: 262 ($whenCondition160,$whenCondition161,$whenCondition162,$whenCondition157,$whenCondition158,$whenCondition159,$whenCondition154,$whenCondition155,$whenCondition156,$whenCondition151,$whenCondition152,$whenCondition153,$whenCondition148,$whenCondition149,$whenCondition150,$whenCondition145,$whenCondition146,$whenCondition147,$whenCondition141,$whenCondition142,$whenCondition143,$whenCondition144,$whenCondition139,$whenCondition140,$whenCondition138,$whenCondition135,$whenCondition136,$whenCondition137,$whenCondition131,$whenCondition132,$whenCondition133,$whenCondition134,$whenCondition129,$whenCondition130,$whenCondition128,$whenCondition125,$whenCondition126,$whenCondition127,$whenCondition121,$whenCondition122,$whenCondition123,$whenCondition124,$whenCondition119,$whenCondition120,$whenCondition118,$whenCondition115,$whenCondition116,$whenCondition117,$whenCondition111,$whenCondition112,$whenCondition113,$whenCondition114,$whenCondition109,$whenCondition110,$whenCondition108,$whenCondition105,$whenCondition106,$whenCondition107,$whenCondition101,$whenCondition102,$whenCondition103,$whenCondition104,$whenCondition99,$whenCondition100,$whenCondition98,$whenCondition96,$whenCondition97,$whenCondition95,$whenCondition93,$whenCondition94,$whenCondition92,$whenCondition90,$whenCondition91,$whenCondition89,$whenCondition87,$whenCondition88,$whenCondition86,$whenCondition84,$whenCondition85,$whenCondition83,$whenCondition81,$whenCondition82,$whenCondition80,$whenCondition78,$whenCondition79,$whenCondition77,$whenCondition75,$whenCondition76,$whenCondition74,$whenCondition72,$whenCondition73,$whenCondition71,$whenCondition69,$whenCondition70,$whenCondition68,$whenCondition66,$whenCondition67,$whenCondition65,$whenCondition63,$whenCondition64,$whenCondition62,$whenCondition60,$whenCondition61,$whenCondition59,$whenCondition57,$whenCondition58,$whenCondition56,$whenCondition54,$whenCondition55,$whenCondition53,$whenCondition51,$whenCondition52,$whenCondition49,$whenCondition50,$whenCondition47,$whenCondition48,$whenCondition46,$whenCondition44,$whenCondition45,$whenCondition43,$whenCondition41,$whenCondition42,$whenCondition40,$whenCondition38,$whenCondition39,$whenCondition37,$whenCondition35,$whenCondition36,$whenCondition34,$whenCondition32,$whenCondition33,$whenCondition31,$whenCondition29,$whenCondition30,$whenCondition28,$whenCondition26,$whenCondition27,$whenCondition25,$whenCondition23,$whenCondition24,$whenCondition22,$whenCondition20,$whenCondition21,$whenCondition19,$whenCondition17,$whenCondition18,$whenCondition16,$whenCondition14,$whenCondition15,$whenCondition13,$whenCondition11,$whenCondition12,$whenCondition10,$whenCondition8,$whenCondition9,$whenCondition7,$whenCondition5,$whenCondition6,$whenCondition4,$whenCondition2,$whenCondition3,$whenCondition1,Gen1.running.value,Gen1.state,Gen1.converter.u,Gen1.limUQDown,Gen1.limUQUp,Gen1.pStatus,Gen1.qStatus,Gen2.running.value,Gen2.state,Gen2.converter.u,Gen2.limUQDown,Gen2.limUQUp,Gen2.pStatus,Gen2.qStatus,Gen3.running.value,Gen3.state,Gen3.converter.u,Gen3.limUQDown,Gen3.limUQUp,Gen3.pStatus,Gen3.qStatus,Gen6.running.value,Gen6.state,Gen6.converter.u,Gen6.limUQDown,Gen6.limUQUp,Gen6.pStatus,Gen6.qStatus,Gen8.running.value,Gen8.state,Gen8.converter.u,Gen8.limUQDown,Gen8.limUQUp,Gen8.pStatus,Gen8.qStatus,Load2.running.value,Load2.state,Load3.running.value,Load3.state,Load4.running.value,Load4.state,Load5.running.value,Load5.state,Load6.running.value,Load6.state,Load9.running.value,Load9.state,Load10.running.value,Load10.state,Load11.running.value,Load11.state,Load12.running.value,Load12.state,Load13.running.value,Load13.state,Load14.running.value,Load14.state,LineB10B11.running.value,LineB10B11.state,LineB12B13.running.value,LineB12B13.state,LineB13B14.running.value,LineB13B14.state,LineB1B2.running.value,LineB1B2.state,LineB1B5.switchOffSignal2.value,LineB1B5.running.value,LineB1B5.state,LineB2B3.running.value,LineB2B3.state,LineB2B4.running.value,LineB2B4.state,LineB2B5.running.value,LineB2B5.state,LineB3B4.running.value,LineB3B4.state,LineB4B5.running.value,LineB4B5.state,LineB6B11.running.value,LineB6B11.state,LineB6B12.running.value,LineB6B12.state,LineB6B13.running.value,LineB6B13.state,LineB7B8.running.value,LineB7B8.state,LineB7B9.running.value,LineB7B9.state,LineB9B10.running.value,LineB9B10.state,LineB9B14.running.value,LineB9B14.state,Tfo1.running.value,Tfo1.state,Tfo2.running.value,Tfo2.state,Tfo3.running.value,Tfo3.state,Bank9.running.value,Bank9.state) * Number of discrete states: 47 (Gen1.running.value,Gen2.running.value,Gen3.running.value,Gen6.running.value,Gen8.running.value,Load2.running.value,Load3.running.value,Load4.running.value,Load5.running.value,Load6.running.value,Load9.running.value,Load10.running.value,Load11.running.value,Load12.running.value,Load13.running.value,Load14.running.value,LineB10B11.running.value,LineB12B13.running.value,LineB13B14.running.value,LineB1B2.running.value,LineB2B3.running.value,LineB2B4.running.value,LineB2B5.running.value,LineB3B4.running.value,LineB4B5.running.value,LineB6B11.running.value,LineB6B12.running.value,LineB6B13.running.value,LineB7B8.running.value,LineB7B9.running.value,LineB9B10.running.value,LineB9B14.running.value,Tfo1.running.value,Tfo2.running.value,Tfo3.running.value,Bank9.running.value,LineB1B5.running.value,Gen2.qStatus,Gen1.qStatus,Gen1.pStatus,Gen3.qStatus,Gen3.pStatus,Gen6.pStatus,Gen8.qStatus,Gen8.pStatus,Gen2.pStatus,Gen6.qStatus) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (419): * Single equations (assignments): 318 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 89 * If-equations: 0 * Equation systems (not torn): 11 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 11 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(124,82)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02489/0.8531, allocations: 13.34 MB / 0.8634 GB, free: 10.97 MB / 0.6856 GB Notification: Performance of simCode: created initialization part: time 0.01849/0.8716, allocations: 7.202 MB / 0.8704 GB, free: 3.719 MB / 0.6856 GB Notification: Performance of simCode: created event and clocks part: time 9.347e-06/0.8716, allocations: 8.5 kB / 0.8704 GB, free: 3.711 MB / 0.6856 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.7.0-maint.1.6.x/Electrical/Machines/SignalN/GeneratorPV.mo:22:5-22:36:writable] Error: The language feature non-linear equations within when-equations is not supported. Suggested workaround: Perform non-linear operations outside the when-equation (this is slower, but works) Error: Internal error function createNonlinearResidualEquations failed [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/SimCode/SimCodeUtil.mo:3563:9-3563:50:writable] Error: Internal error function createOdeSystem failed for component torn nonlinear Equationsystem{{{415:452}, {319:420}, {340:436}, {289:390}, {232:404}, {325:449}, {292:417}, {253:3}, {290:401}, {275:386}, {274:433}, {281:391}, {288:566}, {287:567}, {282:568}, {277:392}, {349:606}, {348:607}, {329:608}, {345:596}, {344:597}, {341:598}, {324:586}, {323:587}, {320:588}, {231:576}, {230:577}, {227:578}, {210:198}, {327:454}, {332:184}, {387:208}, {394:285}, {392:286}, {391:207}, {225:406}, {413:339}, {411:340}, {401:108}, {403:304}, {404:303}, {402:109}, {249:15}, {286:14}, {256:2}, {255:1}, {374:233}, {372:312}, {371:313}, {369:234}, {377:322}, {378:321}, {382:230}, {380:229}, {358:27}, {385:330}, {383:331}, {243:26}, {218:40}, {224:41}, {407:295}, {408:294}, {396:97}, {400:219}, {356:131}, {353:348}, {352:349}, {350:150}, {272:438}, {271:379}, {338:375}, {336:376}, {304:174}, {316:366}, {315:367}, {296:141}, {294:422}, {314:170}, {261:360}, {311:357}, {262:358}, {307:161}}, {212, 211, 214, 213, 355, 239, 215, 216, 219, 223, 291, 226, 229, 228, 217, 412, 414, 221, 220, 237, 238, 388, 390, 241, 240, 276, 245, 246, 247, 248, 279, 278, 284, 283, 280, 244, 251, 285, 250, 252, 254, 257, 366, 379, 363, 367, 373, 365, 364, 361, 359, 258, 357, 384, 386, 360, 362, 381, 370, 375, 368, 376, 233, 234, 405, 406, 235, 236, 398, 397, 409, 410, 399, 222, 389, 393, 395, 242, 260, 259, 264, 263, 295, 298, 267, 269, 268, 270, 273, 300, 305, 308, 337, 339, 343, 342, 346, 302, 301, 317, 318, 297, 306, 312, 313, 310, 309, 265, 266, 354, 351, 333, 334, 335, 347, 303, 322, 321, 299, 293, 326, 328, 331, 330:447, 415, 431, 384, 399, 129, 361, 128, 142, 143, 424, 425, 369, 370, 171, 193, 378, 163, 194, 160, 162, 175, 440, 441, 152, 153, 182, 351, 352, 151, 140, 130, 28, 96, 212, 297, 298, 220, 105, 121, 104, 120, 50, 60, 29, 333, 334, 61, 64, 65, 325, 324, 119, 316, 315, 118, 4, 5, 86, 72, 77, 76, 73, 87, 16, 17, 51, 211, 222, 307, 306, 221, 95, 343, 342, 408, 409, 94, 43, 42, 52, 288, 289, 53, 183, 197, 456, 457, 185, 405, 421, 437, 453, 389, 173, 195, 199, 30, 172, 196, 31, 210, 243, 110, 111, 252, 231, 63, 62, 251, 232, 75, 261, 84, 262, 74, 85, 209, 244, 107, 106, 132, 133, 200} Size: 124 [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/SimCode/SimCodeUtil.mo:1566:5-1566:72:writable] Error: Internal error SimCodeUtil.createEquationsForSystems failed [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/SimCode/SimCodeUtil.mo:821:5-821:146:writable] Error: Internal error function createSimCode failed [Transformation from optimised DAE to simulation code structure failed] " [Timeout remaining time 659] [Calling sys.exit(0), Time elapsed: 3.4466668009990826]