Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_Dynawo.Examples.ENTSOE.TestCase1.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00124/0.00124, allocations: 111.6 kB / 18.13 MB, free: 3.684 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001299/0.001299, allocations: 197.2 kB / 21.43 MB, free: 412 kB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.433/1.433, allocations: 207.6 MB / 232.1 MB, free: 10.96 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/NonElectrical/Logs/package.mo:15:1-17:9:writable] Warning: TimelineKeys was referenced in the package.order file, but was not found in package.mo, TimelineKeys/package.mo or TimelineKeys.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/package.mo): time 0.3172/0.3172, allocations: 71.86 MB / 356.2 MB, free: 14.05 MB / 302.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.6.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(Dynawo.Examples.ENTSOE.TestCase1,fileNamePrefix="Dynawo_Dynawo_Examples_ENTSOE_TestCase1",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Dynawo.Examples.ENTSOE.TestCase1,fileNamePrefix="Dynawo_Dynawo_Examples_ENTSOE_TestCase1",fmuType="me",version="2.0",platforms={"static"}) [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002305/0.002305, allocations: 71.89 kB / 0.5015 GB, free: 9.359 MB / 382.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3441/0.3464, allocations: 67.59 MB / 0.5675 GB, free: 10.46 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.0/Electrical/Controls/Machines/VoltageRegulators/Standard/SEXS.mo:39:81-39:111:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Continuous.mo:1299:5-1299:47:writable] Error: Protected element 'x_scaled' may not be modified, got 'x_scaled(start = {Efd0Pu/K})'. Notification: Performance of FrontEnd: time 0.005574/0.352, allocations: 3.547 MB / 0.571 GB, free: 6.895 MB / 414.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.1573634040541947] Failed to read output from testmodel.py, exit status != 0: 0.35877191508188844 0.37374580700000004 -1.0 Calling exit ...