python3 -m fmpy simulate --output-file Buildings_latest_Buildings.Fluid.Movers.Validation.PowerEuler_res.csv --start-time 0 --stop-time 200 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 0.08 Buildings_latest_Buildings_Fluid_Movers_Validation_PowerEuler.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_dp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in PowerEuler.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in PowerEuler.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve."