(cd run_fmpy && python3 -m fmpy simulate --output-file ../Buildings_13_Buildings.Utilities.Psychrometrics.Functions.BaseClasses.Examples.DewPointTemperatureDerivativeCheck_amb_fmpy_res.csv --start-time -1 --stop-time 1 --timeout 240 --relative-tolerance 1e-09 --interface-type ModelExchange --solver CVode --output-interval 0.0008 ../Buildings_13_Buildings_Utilities_Psychrometrics_Functions_BaseClasses_Examples_DewPointTemperatureDerivativeCheck_amb.fmu) LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 13.0.2-maint.13.x/Utilities/Psychrometrics/Functions/BaseClasses/Examples/DewPointTemperatureDerivativeCheck_amb.mo:17:3-17:115:writable] | | | | The following assertion has been violated at time -0.991200 | | | | ((abs(err) / max(1.0, abs(y)) < 0.01), err=8.448881720403961, y=709.9027580174736) --> "Derivative implementation has an error or solver tolerance is too low."