python3 -m fmpy simulate --output-file BuildingSystems_BuildingSystems.Applications.HeatingSystems.WaterHeatingSystem_res.csv --start-time 0 --stop-time 3.1536e+07 --timeout 50 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 12614.4 BuildingSystems_BuildingSystems_Applications_HeatingSystems_WaterHeatingSystem.fmu LOG_STDOUT | info | ... loading "tab1" from "/tmp/tmp9bm2vz2u/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in WaterHeatingSystem.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in WaterHeatingSystem.pump: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.per.haveWMot_nominal or not (pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in WaterHeatingSystem.pump: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/usr/local/lib/python3.10/dist-packages/fmpy/__main__.py", line 4, in main() File "/usr/local/lib/python3.10/dist-packages/fmpy/command_line.py", line 167, in main result = simulate_fmu(args.fmu_filename, File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 1059, in simulateME state_event, roots_found, time = solver.step(time, t_next) File "/usr/local/lib/python3.10/dist-packages/fmpy/sundials/__init__.py", line 178, in step raise RuntimeError("CVode error (code %s) in module %s, function %s: %s" % self.error_info) RuntimeError: CVode error (code -1) in module CVODE, function CVode: At t = 2180.57, mxstep steps taken before reaching tout.