Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo", uses=false) Using package BuildSysPro with version 3.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Production_Boiler_Boiler",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,fileNamePrefix="BuildSysPro_BuildSysPro_Systems_HVAC_Production_Boiler_Boiler",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.007273/0.007273, allocations: 99.81 kB / 15.73 MB, free: 6.055 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001421/0.001421, allocations: 195.1 kB / 16.67 MB, free: 5.969 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.465/1.465, allocations: 222.9 MB / 240.4 MB, free: 15.13 MB / 206.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo): time 0.9475/0.9475, allocations: 143.1 MB / 433.6 MB, free: 12 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.00128/0.00128, allocations: 64.22 kB / 0.595 GB, free: 12.86 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.195/0.1963, allocations: 82.03 MB / 0.6751 GB, free: 10.94 MB / 0.5137 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.004234/0.2006, allocations: 2.312 MB / 0.6773 GB, free: 8.621 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.001095/0.2017, allocations: 0.4944 MB / 0.6778 GB, free: 8.125 MB / 0.5137 GB