(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --stripRoot --tempDir=temp_TransiEnt_TransiEnt_Consumer_Systems_FridgePoolControl_Pool_mainExplicitFridgePool_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=18000 --stepSize=60 --mode=cs --timeout=240 --tolerance=1e-06 ../TransiEnt_TransiEnt_Consumer_Systems_FridgePoolControl_Pool_mainExplicitFridgePool_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : TransiEnt.Consumer.Systems.FridgePoolControl.Pool.mainExplicitFridgePool (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 18000.000000 - tolerance : 1e-06 - stepSize : 60 LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/FridgePool/fridgePool_N100.mat LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/FridgePool/fridgePool_N100.mat LOG_STDOUT | info | ... loading "A" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/FridgePool/fridgePool_N100.mat" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt warning: [fmi2Warning] mainExplicitFridgePool/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt warning: [fmi2Warning] mainExplicitFridgePool/logStatusWarning: Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.3-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt) not in the resources directory. The FMU might not work as expected if you send it to a different system info: Result file: TransiEnt_TransiEnt_Consumer_Systems_FridgePoolControl_Pool_mainExplicitFridgePool_OMSimulator-cs-euler_res.mat (bufferSize=10) error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable der(pool.fridge[100].x) error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable der(pool.fridge[100].x) LOG_ASSERT | debug | division leads to inf or nan at time 360, (a=-nan) / (b=1.33373), where divisor b is: pool.fridge[100].params.COP error: [stepUntil] fmi2_doStep failed for FMU "mainExplicitFridgePool.root.mainExplicitFridgePool" error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable der(pool.fridge[100].x) Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 7 errors