(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1000 --stepSize=0.4 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_overfilling_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1000.000000 - tolerance : 1e-06 - stepSize : 0.4 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_overfilling_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Tank_overfilling.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.boundaryFore1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.checkValve.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.flowResistance2.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.flowResistance5.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Tank_overfilling.source1.instanceName will not be stored in the result file, because the signal type is not supported warning: [fmi2Warning] Tank_overfilling/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Undirected/Boundaries/Internal/PartialTankUndirected.mo:232: The following assertion has been violated at time 0.520421 ((flowResistance2.inlet.m_flow > tank1.m_flow_assert), flowResistance2.inlet.m_flow=-4810.216266395077, tank1.m_flow_assert=-0.01) --> "Negative massflow at tank inlet" warning: [fmi2Warning] Tank_overfilling/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Undirected/Boundaries/Internal/PartialTankUndirected.mo:232: The following assertion has been violated at time 0.520421 ((checkValve.inlet.m_flow > tank1.m_flow_assert), checkValve.inlet.m_flow=-0.3556473029275047, tank1.m_flow_assert=-0.01) --> "Negative massflow at tank inlet" error: [fmi2logger] [fmi2Error] Tank_overfilling/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:275: The following assertion has been violated at time 0.687343 ((tank1.medium.Xi[1] >= -1e-5 and tank1.medium.Xi[1] <= 1.00001), tank1.medium.Xi[1]=-0.01232078704251971) --> "Mass fraction X[1] = -0.0123208of substance Air of medium JP8 and DryAir is not in the range 0..1" error: [fmi2logger] [fmi2Error] Tank_overfilling/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "Tank_overfilling.root.Tank_overfilling" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:275:11-278:41:writable] | | | | The following assertion has been violated at time 0.687343 | | | | ((tank1.medium.Xi[1] >= -1e-5 and tank1.medium.Xi[1] <= 1.00001), tank1.medium.Xi[1]=-0.01232078705499343) --> "Mass fraction X[1] = -0.0123208of substance Air | | | | of medium JP8 and DryAir is not in the range 0..1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:275:11-278:41:writable] | | | | The following assertion has been violated at time 0.687343 | | | | ((tank1.medium.Xi[2] >= -1e-5 and tank1.medium.Xi[2] <= 1.00001), tank1.medium.Xi[2]=1.01232078705511) --> "Mass fraction X[2] = 1.01232of substance Jet propulsion 8 (JetA with additives) | | | | of medium JP8 and DryAir is not in the range 0..1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:283:7-284:76:writable] | | | | The following assertion has been violated at time 0.687343 | | | | ((tank1.medium.p >= 0.0), tank1.medium.p=-19837633.64069626) --> "Pressure (= -1.98376e+07 Pa) of medium "JP8 and DryAir" is negative | | | | (Temperature = 271.747 K)" Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 2 warnings info: 3 errors