(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_fillingClosedTank_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=20 --stepSize=0.008 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Undirected_Boundaries_Tests_Tank_fillingClosedTank_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 20.000000 - tolerance : 1e-06 - stepSize : 0.008 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Undirected.Boundaries.Tests.Tank_fillingClosedTank_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Tank_fillingClosedTank.acceleration.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.flowResistance3.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Tank_fillingClosedTank.staticHead2.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Undirected/Boundaries/Internal/PartialTankUndirected.mo:232:5-235:36:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((flowResistance.inlet.m_flow > tank.m_flow_assert), flowResistance.inlet.m_flow=-0.02996909920257167, tank.m_flow_assert=-0.01) --> "Negative massflow at tank inlet"