(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.TransportDelay_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Processes_Tests_TransportDelay_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=2.5 --stepSize=0.0025 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Processes_Tests_TransportDelay_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Processes.Tests.TransportDelay (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 2.500000 - tolerance : 1e-06 - stepSize : 0.0025 info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Processes.Tests.TransportDelay_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable TransportDelay.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.flowResistance1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.sink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.sink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.sink1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.sink1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.sink1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.source1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.transportDelay.instanceName will not be stored in the result file, because the signal type is not supported info: Variable TransportDelay.transportDelay1.instanceName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] TransportDelay/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Utilities/Streams.mo:113: The arguments u_min and u_max provided in the function call solveOneNonlinearEquation(f,u_min,u_max) do not bracket the root of the single non-linear equation 0=f(u): u_min = 200 u_max = 6000 fa = f(u_min) = -2.30143e+09 fb = f(u_max) = -2.29411e+09 fa and fb must have opposite sign which is not the case error: [fmi2logger] [fmi2Error] TransportDelay/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "TransportDelay.root.TransportDelay" error: [fmi2logger] [fmi2Error] TransportDelay/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/Utilities/Streams.mo:113: The arguments u_min and u_max provided in the function call solveOneNonlinearEquation(f,u_min,u_max) do not bracket the root of the single non-linear equation 0=f(u): u_min = 200 u_max = 6000 fa = f(u_min) = -2.30143e+09 fb = f(u_max) = -2.29411e+09 fa and fb must have opposite sign which is not the case error: [fmi2logger] [fmi2Error] TransportDelay/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable transportDelay1.displayRadius Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 0 warnings info: 6 errors