(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_compressibilityFactor_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] compressibilityFactor/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((perfectGas.p_min >= 611.657 and perfectGas.p_min <= 1e8), perfectGas.p_min=100) --> "Variable violating min/max constraint: 611.657 <= perfectGas.p_min <= 1e8, has value: 100" warning: [fmi2Warning] compressibilityFactor/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((idealGas.p_min >= 611.657 and idealGas.p_min <= 1e8), idealGas.p_min=100) --> "Variable violating min/max constraint: 611.657 <= idealGas.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.compressibilityFactor_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable compressibilityFactor.idealGas.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.idealGas.instanceName will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.perfectGas.adiabaticModel.name will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.perfectGas.instanceName will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.sink1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable compressibilityFactor.source1.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:54:3-56:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(idealGas.adiabaticModel.Z_in >= 0.9523809523809523) and noEvent(idealGas.adiabaticModel.Z_in <= 1.05)), idealGas.adiabaticModel.Z_in=0.9498011403970017) --> "In "compressibilityFactor.idealGas.adiabaticModel" the inlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:57:3-59:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(idealGas.adiabaticModel.Z_out >= 0.9523809523809523) and noEvent(idealGas.adiabaticModel.Z_out <= 1.05)), idealGas.adiabaticModel.Z_out=0.9498012556672215) --> "In "compressibilityFactor.idealGas.adiabaticModel" the outlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:54:3-56:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(perfectGas.adiabaticModel.Z_in >= 0.9523809523809523) and noEvent(perfectGas.adiabaticModel.Z_in <= 1.05)), perfectGas.adiabaticModel.Z_in=0.9498011403970017) --> "In "compressibilityFactor.perfectGas.adiabaticModel" the inlet state deviates from ideal gas behaviour beyond the specified tolerance." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/AdiabaticThermodynamicModels/BaseClasses/PartialIdealGas.mo:57:3-59:20:writable] | | | | The following assertion has been violated at time 0.050000 | | | | ((noEvent(perfectGas.adiabaticModel.Z_out >= 0.9523809523809523) and noEvent(perfectGas.adiabaticModel.Z_out <= 1.05)), perfectGas.adiabaticModel.Z_out=0.9498012556672215) --> "In "compressibilityFactor.perfectGas.adiabaticModel" the outlet state deviates from ideal gas behaviour beyond the specified tolerance." info: 2 warnings info: 0 errors