(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Fixed3_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Fixed3_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Tests_Processes_Adiabatic_Fixed3_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Fixed3 (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] Fixed3/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Interfaces.mo:2463: The following assertion has been violated at time 0.000000 ((adiabatic.outlet.state.T >= 273.15 and adiabatic.outlet.state.T <= 373.15), adiabatic.outlet.state.T=373.3369106792701) --> "Variable violating min/max constraint: 273.15 <= adiabatic.outlet.state.T <= 373.15, has value: 373.337" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Tests.Processes.Adiabatic.Fixed3_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Fixed3.adiabatic.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.adiabaticFilter.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.sink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.sink1.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source1.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source1.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source1.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source1.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Fixed3.source1.instanceName will not be stored in the result file, because the signal type is not supported info: 1 warnings info: 0 errors