(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.Volumes.Reservoir_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_Volumes_Reservoir_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=100 --stepSize=0.1 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_Volumes_Reservoir_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.Volumes.Reservoir (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 100.000000 - tolerance : 1e-06 - stepSize : 0.1 warning: [fmi2Warning] Reservoir/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((massFlowRate.p_min >= 611.657 and massFlowRate.p_min <= 1e8), massFlowRate.p_min=100) --> "Variable violating min/max constraint: 611.657 <= massFlowRate.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Reservoir/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((isenthalpic.p_min >= 611.657 and isenthalpic.p_min <= 1e8), isenthalpic.p_min=100) --> "Variable violating min/max constraint: 611.657 <= isenthalpic.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.Volumes.Reservoir_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Reservoir.isenthalpic.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.massFlowRate.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.reservoir.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.source.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.source.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.source.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.source.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Reservoir.source.instanceName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Idealized/Processes/Isenthalpic.mo:53:3-56:20:writable] | | | | The following assertion has been violated at time 92.000000 | | | | ((noEvent(massFlowRate.m_flow_fixed * isenthalpic.dpLoss >= -2.220446049250313e-16)), massFlowRate.m_flow_fixed=1, isenthalpic.dpLoss=-10.27574475674191) --> "In "Reservoir.isenthalpic" the pressure rises in the direction of the flow. | | | | An isenthalpic pressure increase however violates the second law of thermodynamics." info: 2 warnings info: 0 errors