(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step6MassFlowRateStep_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_ClausiusRankine_Step6MassFlowRateStep_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_ClausiusRankine_Step6MassFlowRateStep_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.ClausiusRankine.Step6MassFlowRateStep (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] Step6MassFlowRateStep/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((massFlowRateSource.p_min >= 611.657 and massFlowRateSource.p_min <= 1e8), massFlowRateSource.p_min=100) --> "Variable violating min/max constraint: 611.657 <= massFlowRateSource.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step6MassFlowRateStep/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((superheater.p_min >= 611.657 and superheater.p_min <= 1e8), superheater.p_min=100) --> "Variable violating min/max constraint: 611.657 <= superheater.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step6MassFlowRateStep/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((preheater.p_min >= 611.657 and preheater.p_min <= 1e8), preheater.p_min=100) --> "Variable violating min/max constraint: 611.657 <= preheater.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step6MassFlowRateStep/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((boiler.p_min >= 611.657 and boiler.p_min <= 1e8), boiler.p_min=100) --> "Variable violating min/max constraint: 611.657 <= boiler.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step6MassFlowRateStep/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8), turbine.p_min=100) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step6MassFlowRateStep/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((pump.p_min >= 611.657 and pump.p_min <= 1e8), pump.p_min=100) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step6MassFlowRateStep_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Variable Step6MassFlowRateStep.boiler.instanceName will not be stored in the result file, because the signal type is not supported info: Parameter Step6MassFlowRateStep.efficiencyExtensive.description will not be stored in the result file, because the signal type is not supported info: Parameter Step6MassFlowRateStep.efficiencySpecific.description will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.massFlowRateSource.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.preheater.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.pump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.superheater.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.turbine.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.waterSink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.waterSource.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.waterSource.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.waterSource.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.waterSource.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Step6MassFlowRateStep.waterSource.instanceName will not be stored in the result file, because the signal type is not supported info: 6 warnings info: 0 errors