(cd run_OMSimulator-cs-euler && /home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --resultFile=../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step2SaturatedVapor_OMSimulator-cs-euler_res.mat --stripRoot --tempDir=temp_ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_ClausiusRankine_Step2SaturatedVapor_OMSimulator-cs-euler_fmu --startTime=0 --stopTime=1 --stepSize=0.01 --mode=cs --timeout=240 --tolerance=1e-06 ../ThermofluidStream_dev_ThermofluidStream_Idealized_Examples_ClausiusRankine_Step2SaturatedVapor_OMSimulator-cs-euler.fmu) info: *** FMU Simulation Info *** - model : ThermofluidStream.Idealized.Examples.ClausiusRankine.Step2SaturatedVapor (co-simulation) - fmiVersion: 2.0 - startTime : 0.000000 - stopTime : 1.000000 - tolerance : 1e-06 - stepSize : 0.01 warning: [fmi2Warning] Step2SaturatedVapor/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((flowResistance.p_min >= 611.657 and flowResistance.p_min <= 1e8), flowResistance.p_min=100) --> "Variable violating min/max constraint: 611.657 <= flowResistance.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step2SaturatedVapor/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((preheaterAndBoiler.p_min >= 611.657 and preheaterAndBoiler.p_min <= 1e8), preheaterAndBoiler.p_min=100) --> "Variable violating min/max constraint: 611.657 <= preheaterAndBoiler.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step2SaturatedVapor/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((turbine.p_min >= 611.657 and turbine.p_min <= 1e8), turbine.p_min=100) --> "Variable violating min/max constraint: 611.657 <= turbine.p_min <= 1e8, has value: 100" warning: [fmi2Warning] Step2SaturatedVapor/logStatusWarning: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Interfaces/SISOFlow.mo:27: The following assertion has been violated at time 0.000000 ((pump.p_min >= 611.657 and pump.p_min <= 1e8), pump.p_min=100) --> "Variable violating min/max constraint: 611.657 <= pump.p_min <= 1e8, has value: 100" info: Result file: ../ThermofluidStream_dev_ThermofluidStream.Idealized.Examples.ClausiusRankine.Step2SaturatedVapor_OMSimulator-cs-euler_res.mat (bufferSize=10) info: Parameter Step2SaturatedVapor.efficiency.description will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.flowResistance.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.preheaterAndBoiler.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.pump.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.turbine.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSink.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSink.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSink.instanceName will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSource.displayPos1 will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSource.displayPos2 will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSource.displayPos3 will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSource.displayPos4 will not be stored in the result file, because the signal type is not supported info: Variable Step2SaturatedVapor.waterSource.instanceName will not be stored in the result file, because the signal type is not supported error: [fmi2logger] [fmi2Error] Step2SaturatedVapor/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Water/IF97_Utilities.mo:3022: IF97 medium function tsat called with too low pressure p = 100 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] Step2SaturatedVapor/logFmi2Call: fmi2DoStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "Step2SaturatedVapor.root.Step2SaturatedVapor" error: [fmi2logger] [fmi2Error] Step2SaturatedVapor/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.4.1-main/Media/myMedia/Water/IF97_Utilities.mo:3022: IF97 medium function tsat called with too low pressure p = 100 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] [fmi2Error] Step2SaturatedVapor/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable waterSource.xiFromInput Traceback (most recent call last): File "", line 198, in _run_module_as_main File "", line 88, in _run_code File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/__main__.py", line 38, in sys.exit(main()) ~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 309, in main handler(args.model, args) ~~~~~~~^^^^^^^^^^^^^^^^^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/cli.py", line 176, in _runFMU fmu.simulate() ~~~~~~~~~~~~^^ File "/home/hudson/saved_omc/OMSimulator/install/lib/x86_64-linux-gnu/OMSimulator/fmu.py", line 906, in simulate raise RuntimeError(f"Failed to simulate model: {status}") RuntimeError: Failed to simulate model: Status.error info: 4 warnings info: 6 errors